Interference Screw versus Cement Fixation in Anterior Cruciate Ligament Soft Tissue Grafts: A Biomechanical Study

Author:

Patel Jay1ORCID,Kadkoy Yazan1ORCID,Helbig Thomas1,Rupani Mohammed1,Cuppari Nicholas1,Cortes Ricardo1,Wetterstrand Charlene1,Lu Michael T.2,Paglia David N.1,Galdi Balazs1,Beiro Cristobal2

Affiliation:

1. Department of Orthopaedics, Rutgers New Jersey Medical School, Newark, New Jersey

2. Department of Sports Medicine & Arthroscopic Surgery, University Orthopaedic Associates, Somerset, New Jersey

Abstract

AbstractShortcomings of fixation have been reported as a source of graft failure in anterior cruciate ligament (ACL) reconstruction. While interference screws have long been used as fixation devices for ACL reconstruction, they are not without complications. Previous studies have highlighted the use of bone void filler as a fixation method; however, no biomechanical comparisons using soft tissue grafts with interference screws exist to our knowledge. The purpose of this study is to evaluate the fixation strength of a calcium phosphate cement bone void filler compared with screw fixation in an ACL reconstruction bone replica model with human soft tissue grafts. In total, 10 ACL grafts were constructed using semitendinosus and gracilis tendons harvested from 10 donors. Grafts were affixed with either an 8–10 mm × 23 mm polyether ether ketone interference screw (n = 5) or with approximately 8 mL of calcium phosphate cement (n = 5) into open cell polyurethane blocks. Graft constructs were tested to failure in cyclic loading under displacement control at a rate of 1 mm per second. When compared with screw construct, the cement construct showed a 978% higher load at yield, 228% higher load at failure, 181% higher displacement at yield, 233% higher work at failure, and a 545% higher stiffness. Normalized data for the screw constructs relative to the cement constructs from the same donor showed 14 ± 11% load at yield, 54 ± 38% load at failure, and 172 ± 14% graft elongation. The results of this study indicate that cement fixation of ACL grafts may result in a stronger construct compared with the current standard of fixation with interference screws. This method could potentially reduce the incidence of complications associated with interface screw placement such as bone tunnel widening, screw migration, and screw breakage.

Publisher

Georg Thieme Verlag KG

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3