Cerebellopontine Angle Surgery Assisted by Continuous Mapping of the Facial Nerve Via the Ultrasonic Aspirator

Author:

Cenzato Marco1,Stefini Roberto2,Zenga Francesco3,Piparo Maurizio1,Debernardi Alberto1,Costi Ilaria4,Fava Enrica5ORCID

Affiliation:

1. Department of Neurosurgery, Great Niguarda Hospital, Milano, Lombardia, Italy

2. Department of Neurosurgery, Ospedale Civile di Legnano, Legnano, Lombardia, Italy

3. Department of Neurosurgery, Azienda Ospedaliero Universitaria Città della Salute e della Scienza di Torino, Torino, Piemonte, Italy

4. Department of Neurophysiology, Great Niguarda Hospital, Milano, Lombardia, Italy

5. Department of Neurosurgery, Great Niguarda Hospital, Università degli Studi di Milano BIOMETRA,, Milano, Lombardia, Italy

Abstract

Abstract Background Cerebellopontine angle (CPA) surgery carries the risk of lesioning the facial nerve. The goal of preserving the integrity of the facial nerve is usually pursued with intermittent electrical stimulation using a handheld probe that is alternated with the resection. We report our experience with continuous electrical stimulation delivered via the ultrasonic aspirator (UA) used for the resection of a series of vestibular schwannomas. Methods A total of 17 patients with vestibular schwannomas, operated on between 2010 and 2018, were included in this study. A constant-current stimulator was coupled to the UA used for the resection, delivering square-wave pulses throughout the resection. The muscle responses from upper and lower face muscles triggered by the electrical stimulation were displayed continuously on multichannel neurophysiologic equipment. The careful titration of the electrical stimulation delivered through the UA while tapering the current intensity with the progression of the resection was used as the main strategy. Results All operations were performed successfully, and facial nerve conduction was maintained in all patients except one, in whom a permanent lesion of the facial nerve followed a miscommunication to the neurosurgeon. Conclusion The coupling of the electrical stimulation to the UA provided the neurosurgeon with an efficient and cost-effective tool and allowed a safe resection. Positive responses were obtained from the facial muscles with low current intensity (lowest intensity: 0.1 mA). The availability of a resection tool paired with a stimulator allowed the surgeon to improve the surgical workflow because fewer interruptions were necessary to stimulate the facial nerve via a handheld probe.

Publisher

Georg Thieme Verlag KG

Subject

Clinical Neurology,Surgery

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3