An Early Investigation into Possible Alternatives to Stapled Hysterotomy in Open Fetal Surgery

Author:

Church Joseph T.1,McLeod Jennifer S.1,Coughlin Megan A.1,Bergin Ingrid L.2,Perkins Elena M.1,Hoffman Hayley R.1,Bilger Mark1,Rojas-Peña Alvaro1,Treadwell Marjorie C.3,Berman Deborah R.3,Jarboe Marcus D.4,Mychaliska George B.4,Perrone Erin E.4

Affiliation:

1. Extracorporeal Life Support Laboratory, Department of Surgery, Michigan Medicine, University of Michigan, Ann Arbor, Michigan

2. Unit for Laboratory Animal Medicine, University of Michigan, Ann Arbor, Michigan

3. Department of Obstetrics and Gynecology, Fetal Diagnosis and Treatment Center, Michigan Medicine, University of Michigan, Ann Arbor, Michigan

4. Department of Surgery, Fetal Diagnosis and Treatment Center, Michigan Medicine, University of Michigan, Ann Arbor, Michigan

Abstract

Purpose We hypothesized that surgical energy could be used to create hysterotomies in open fetal surgery. Study Design Initial studies compared the LigaSure Impact and Harmonic ACE + 7 Shears in the efficiency of hysterotomy and thermal damage. Pregnant ewes at an estimated gestational age (EGA) of 116 to 120 days (term = 145; n = 7) underwent hysterotomy using either device. Hysterotomy edges were resected, and thermal injury extent was determined by histopathological assessment. Upon determining a superior device, subsequent studies compared this to the AutoSuture Premium Poly CS*-57 Stapler in uterine healing. Pregnant ewes (n = 6) at an EGA of 87 to 93 days underwent 6-cm hysterotomy in each gravid horn with either the stapler (n = 5) or Harmonic (n = 5) followed by closure and animal recovery. After 37 to 42 days, uterine healing was assessed by evaluating tensile strength and histopathology. Results Thermal damage was more extensive with the LigaSure (n = 11 hysterotomies) than with the Harmonic (n = 11; 5.6 ± 1 vs. 3.1 ± 0.6 mm; p < 0.0001);therefore, the Harmonic was selected for healing studies. Gross scar appearance and tensile strength were the same between the Harmonic and stapler. The stapler caused more fibrosis (4/7 samples with “moderate” fibrosis vs. 0/8 with the Harmonic; p = 0.02). Conclusion The Harmonic ACE + 7 caused less thermal injury than the LigaSure Impact and performed similar to the CS*-57 Stapler in uterine healing with continued gestation.

Publisher

Georg Thieme Verlag KG

Subject

Obstetrics and Gynecology,Pediatrics, Perinatology and Child Health

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3