Bestimmung des zerebralen Blutflusses mittels des 81 Rb/81 mKr-Generatorsystems
-
Published:1990
Issue:01
Volume:29
Page:7-12
-
ISSN:0029-5566
-
Container-title:Nuklearmedizin
-
language:de
-
Short-container-title:Nuklearmedizin
Author:
Bialy J.,Hans F.-J.,Oberhausen E.,Peters W.J.,Schmitt M.,Warnke R,Schroth H.-J.
Abstract
A method is being developed which not only measures cerebral blood flow as a static quantity but also its changes with time. For that purpose a semiconductor device ascertains the proportion of intracerebral81 Rb and 81mKr activities. By opening the haemato-encephalic barrier in animal experiments a sufficient concentration of intracerebral81 Rb could be attained and the modified blood circulation after step-wise ligature of all brain arteries brought into relation to the corresponding Rb/Kr quotient. Over the range from undisturbed to completely interrupted cerebral blood flow this quotient varied up to 25% of its initial value.