Multi-Center Study of Replacement of the International Reference Preparation for Thromboplastin, Rabbit, Plain

Author:

van den Besselaar A M. H. P1

Affiliation:

1. The Haemostasis and Thrombosis Research Center, Department of Haematology, Leiden University Hospital, Leiden, The Netherlands

Abstract

SummaryA multi-center study of the three W.H.O. international reference preparations (IRP) for thromboplastin has been performed. The main purpose of the study was the determination of the mean international sensitivity index (ISI) of a proposed replacement IRP for thromboplastin, rabbit, plain. Twenty laboratories in Europe, North America, and Australasia participated in the study. All clotting times were determined with the manual technique. The inter-laboratory variation of the ISI was considered as the relevant parameter for assessment of ISI precision. Low interlaboratory variation was observed in the calibration of rabbit thromboplastin against rabbit thromboplastin (2.9-3.0% coefficient of variation of calibration line slope). Relatively high interlaboratory variation was observed in the calibration of rabbit against human thromboplastin (3.7–7.2 CV). Intermediary interlaboratory variation was obtained in the comparison of rabbit or human plain thromboplastin with bovine combined thromboplastin (3.5-4.0% CV). These findings confirm the principle of like-to-like calibration in biological standardization.The mean ISI values based on the IRP for rabbit thromboplastin (RBT/79) are in excellent agreement with those obtained with the IRP for bovine thromboplastin (OBT/79). In contrast, the mean ISI values determined with the IRP for human thromboplastin (BCT/253) were 6% lower than those with RBT/79. This bias may be caused by a difference in design of the two historical calibration studies. The mean ISI of the proposed replacement IRP for thromboplastin, rabbit, plain obtained by calibration against RBT/79 was 1.035 (standard error: 0.027). It is recommended to round the mean ISI off to 1.0.Opportunity was also taken to compare a lyophilized normal pooled plasma with fresh individual normal plasmas. The mean PT-ratio of this lyophilized plasma obtained with RBT/79, and BCT/253 was 1.02, which was slightly but significantly higher than the mean PT-ratio obtained with OBT/79 (0.99).INR equivalents were determined for a lyophilized pooled plasma derived from patients treated with oral anticoagulants. There were small but significant differences between the various thromboplastins, which may be caused by slight activation of the plasma or by the lyophilization process.

Publisher

Georg Thieme Verlag KG

Subject

Hematology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3