Properties of Thrombin and Fibrinogen

Author:

Baughman D. J,Waugh D. F,Juvkam-Wold Constance

Abstract

SummaryA standard clotting system has been analysed according to the average clotting time and variations due to thrombin, fibrinogen, day-to-day preparation of reagents and the clotting assay itself. The variations, εT, εF and ετ are reproducible and normally distributed with zero mean.Transfer of thrombin into a vessel produces adsorption losses at the solution-air (S/A) and solution-wall (S/W) interfaces. Specific loss at τ = 30 sec = (% loss in τ) (thrombin volume)/surface area. For clean non-polar surfaces such as polyethylene or paraffin the average S/W loss of 3.8%-cm (0.77 mg/m2) has the large coefficient of variation of 3.2%. Vessel surfaces may be saturated by prior conditioning using a thrombin concentration tenfold that required to give τ = 50 sec. Emptying and immediately refilling now gives an S/W loss of 0.19%-cm (0.04 mg/m2). The specific S/A loss, always present, is 2.7%-cm (0.54 mg/m2). The combined average loss for conditioned vessels is 1.0% at τ = 30 sec and is reproducible within sτ 2 for single vessels. A set of vessels gives a coefficient of variation of 0.53%.Stock fibrinogen aliquots are stored frozen at —95° and are thawed and diluted under standard conditions. If a syringe is used to withdraw clotting tube aliquots, SF2 is significantly increased over that obtained by using pipettes. Since pipettes do not contribute, the observed coefficient of variation of 1.7% then applies to the variation between tubes of stock-F. Six different lots of Fraction I gave a coefficient of variation of 12% between lot numbers.Experiments revealed a variance between equivalent experiments performed on different days (coefficient of variation 1.9%). Within this variance pairs of stock reagents were stable within the maximum limits of ± 0.12% of τ per day. There is no reason to suspect that either stock reagent has an intrinsic instability. The day-to-day variance given above arises from non-reproducibilities in the preparation of buffer diluents. Variances were reduced when buffers were prepared in deaerated water at room temperature.The total day-to-day coefficient of variation of fibrinogen of 1.5% and the variation between fibrinogen lots effectively eliminates this reagent as a reference standard. Thrombin appeared otherwise : by selecting and reusing reservoirs the maximum total thrombin day-to-day coefficient of variance is 0.36%. Thus, 95% of the thrombin concentrations prepared on different days will lie within 0.72% of the true value. By making use of known purification procedures it is possible to reproduce a stock thrombin reagent. This would serve as a universal standard.

Funder

National Science Foundation and the Institute of General Medical Sciences of the National Institutes of Health

Publisher

Georg Thieme Verlag KG

Subject

Hematology

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Interactions of bovine thrombin and plasma albumin with low-energy surfaces;Journal of Biomedical Materials Research;1978-09

2. Some Effects of Calcium on the Activation of Human Factor VIII/Von Willebrand Factor Protein by Thrombin;Journal of Clinical Investigation;1977-10-01

3. The interactions of thrombin with borosilicate glass surfaces;Journal of Biomedical Materials Research;1975-09

4. Interactions of bovine fibrinogen and thrombin;Archives of Biochemistry and Biophysics;1975-06

5. Specific Activities of Bovine Thrombin and Thrombin Components;Thrombosis and Haemostasis;1972

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3