The Value of an Automated Ultrasound System in the Detection of Synovitis

Author:

Mueller Ruediger12,Grunke Mathias2,Wendler Jörg3,Schuch Florian4,Hofmann-Preiss Karina5,Boettger Ina5,Jakobs Rüdiger6,Schulze-Koops Hendrik2,von Kempis Johannes1

Affiliation:

1. Division of Rheumatology, Kantonsspital St. Gallen, St. Gallen, Switzerland

2. Munich University Hospital, Division of Rheumatology, Munich, Germany

3. Schwerpunktpraxis Rheumatologie, Rheumatologie, Erlangen, Germany

4. Schwerpunktpraxis Rheumatologie, Schwerpunktpraxis Rheumatologie, Erlangen, Germany

5. Institut für bildgebende Diagnostik und Therapie, BDT - MVZ Träger GmbH, Erlangen, Germany

6. Siemens Healthcare GmbH, Ultrasound, Erlangen, Germany

Abstract

Abstract Background The detection of joint swelling caused by synovitis is important for the diagnosis of inflammatory arthritis. Ultrasound (US) and MRI have proven to be more sensitive and reliable than physical examination, but they are time-consuming and expensive. The automated breast volume scanner was developed to acquire serial B-mode pictures of the female breast and these can be analyzed in all three dimensions. Objectives To analyze the value of automated B-mode ultrasound employing the ABVS system in detecting synovitis of the finger joints compared to manual ultrasound (mUS) and physical examination, using MRI as the gold standard. Methods 19 consecutive patients suffering from active rheumatoid (n=15) or psoriatic (n=4) arthritis were included. Automated and mUS were conducted with a linear array (ACUSON S2000™, 11 MHz). Multiplanar reconstruction enabled examination of the images for the presence of synovitis. Results 90% of the hand joints were assessable by automated ultrasound. Automated US detected 12.0, mUS 14.2, MRI 13.4, and clinical examination 4.1 positive joints – i. e. joints with synovitis - on average per patient. The inter-observer reliability of both assessors for automated and mUS, MRI, and physical examination, was 66.9%, 72.7%, 95.1%, and 88.9%, respectively. 84.3% of the joints classified as positive on MRI were confirmed by automated ultrasound, 85.5% on mUS, and 36.0 on physical examination. This translated into a sensitivity of 83.5%, 85.5%, and 36.0% for the three methods, respectively. Conclusion: Automated ultrasound is a promising ultrasound method for assessing small joints in patients with inflammatory arthritis.

Publisher

Georg Thieme Verlag KG

Subject

Radiology Nuclear Medicine and imaging

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3