Acquisition of a Dose Management System with Consideration of Medico-Legal and Economic Aspects

Author:

Do Thuy Duong1ORCID,Melzig Claudius2,Kauczor Hans-Ulrich2,Weber Marc-André3ORCID,Wielpütz Mark Oliver24

Affiliation:

1. Department of Clinical Radiology, University of Heidelberg, Germany

2. Department of Diagnostic and Interventional Radiology, University of Heidelberg, Germany

3. Universitätsmedizin Rostock, Diagnostische und Interventionelle Radiologie, Rostock, Germany

4. Translational Lung Research Center TLRC Heidelberg, German Center for Lung Research DZL, Heidelberg, Germany

Abstract

Background New radiation protection regulation encompassing additional obligations for monitoring, reporting and recording of radiation exposure, was enacted on December 31, 2018. As a consequence, dose management systems (DMS) are necessary to fulfill the requirements. The process of selection, acquisition and implementation of a suitable IT solution for this purpose is a challenge that all X-ray-applying facilities, including hospitals and private practices, are currently facing. Method A target/actual-analysis as well as a cost-utility analysis is presented for this specific case as a foundation for the acquisition decision-making process. Result An actual analysis is necessary in order to record the current status of dose documentation. An interdivisional approach is recommended to include all imaging modalities and devices. An interdisciplinary steering committee can be helpful in enabling consensus and rapid action. A target analysis includes additional criteria with respect to ease of operation, technical feasibility, process optimization and research opportunities to consider in addition to the statutory requirements. By means of a cost-benefit analysis, considerations between costs and the individually weighted advantages and disadvantages of eligible DMS result in a ranking of preference for the available solutions. Conclusion Requirements of a DMS can be summarized in a specification sheet. Deploying an actual condition analysis, target state analysis and cost-utility analysis can help to identify a suitable DMS to achieve rapid commissioning and highest possible user acceptance while optimizing costs at the same time. Key Points: Citation Format

Publisher

Georg Thieme Verlag KG

Subject

Radiology, Nuclear Medicine and imaging

Reference9 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3