Intraoperative Imaging in Pelvic Surgery

Author:

Keil Holger1,Aytac Sara1,Grützner Paul Alfred1,Franke Jochen1

Affiliation:

1. Klinik für Unfall- und orthopädische Chirurgie, BG Unfallklinik Ludwigshafen

Abstract

AbstractPelvic fractures may range from highly severe, life-threatening injuries to less acute clinical entities. There are several sub-entities that are summed up as pelvic injuries. Anatomically, there are fractures of the anterior or posterior pelvic ring. Apart from these, there are fractures of the acetabulum that make up about one fifth of all pelvic injuries. The indication for surgical treatment of pelvic ring injuries depends on the type of injury, involvement of anterior and/or posterior elements of the pelvic ring, demands and the general condition of the patient. In acetabular fractures, indications depend on the dislocation of the fracture and of course also the needs of the patient and his general condition. An intraarticular step-off of more than 2 mm is usually considered as an indication for open reduction and osteosynthesis. Usually in all these injuries, a preoperative CT scan is mandatory to allow precise planning of the operative approach and technique. Intraoperatively, the surgeon should be familiar with the acquisition of the 2D standard views, including 2D imaging of the pelvic ring and the acetabulum. These consist of the anteroposterior view for both pelvic ring and acetabular osteosyntheses. For further assessment of pelvic ring treatments, inlet and outlet views are achievable by angulating the C-arm cranially and caudally. To assess aspects of the anterior and posterior column of the acetabulum, iliac oblique views are used. Here, the C-arm is rotated laterally. As evaluation of 2D views can be limited due to anatomy and superposing structures, intraoperative 3D imaging has become common in the last decade. Special C-arms allow the automatic acquisition of large numbers of projections and create CT-like views of the central volume. Although this method has significantly widened the possibilities of intraoperative imaging, some issues remain. Depending on the amount of implants placed in the imaging field, assessment can be seriously impaired due to artefacts caused by the implants. Intraoperative CT imaging promises enhanced image quality for artefacts and allows a considerably larger field of view. The use of radiation-free navigation facilitates implant placement in minimally invasive procedures like screw placement in the sacroiliacal joint or the acetabulum by visualisation of instruments and implants in a pre- or intraoperative 3D data set.

Publisher

Georg Thieme Verlag KG

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3