Ultrasound Examination of the Pupil – A New Tool for the Neuro-Ophthalmological Assessment

Author:

Farina Filippo1,Vosko Milan R.2,Baracchini Claudio1,Ermani Mario3,Sommer Peter4,Greisenegger Stefan5,Laubichler Peter6,Struhal Walter7,Kellermair Lukas2,Ransmayr Gerhard2,Brunner Cornelia7

Affiliation:

1. Department of Neuroscience, University of Padua School of Medicine, Stroke Unit and Neurosonology Laboratory, Padova, Italy

2. Department of Neurology 2, Kepler Universitätsklinikum, Med Campus III, Stroke Unit and Neurosonology Laboratory, Linz, Austria

3. Department of Neuroscience, University of Padua School of Medicine, Neurological Clinic, Padova, Italy

4. Department of Neurology, Krankenanstalt Rudolfstiftung Vienna, Austria

5. Department of Neurology, Medical University of Vienna, Austria

6. Department of Ophtalomology and Optometry, Kepler University Hospital GmbH, Johannes Kepler University Linz, Austria

7. Department of Neurology, University Clinic Tulln, Karl Landsteiner University of Health Sciences, Site Tulln, Austria

Abstract

Abstract Background Pupil examination represents a diagnostic and prognostic test in the management of several neurological diseases. Infrared video pupillometry (IVP) is the gold standard, since it is not routinely available, a noninvasive bedside ultrasound assessment has been proposed as an alternative. The aim of this study was to assess the feasibility and reproducibility of ultrasound pupillometry (UP) in comparison with IVP. Materials and Methods 81 subjects (43 men and 38 women, mean age: 52 ± 20 years and 49 ± 19 years, respectively) with no history of neurophthalmologic disease were enrolled. UP was performed with a 12-MHz linear probe according to current guidelines for orbital insonation. Light and painful stimuli were applied to test pupillary light reflex (PLR) and ciliospinal reflex (CR). In 30 of these subjects IVP examination was performed additionally to obtain intra-observer and inter-observer agreement. Results Increasing age was associated with a decreased pupillary diameter (PD) at rest, after PLR and CR (R –0.728, p < 0.01, R –0.643, p < 0.01, R 0.674, p < 0.001 respectively), while no association was noticed with time to constriction/dilation. UP measurements were reproducible (rate of inter- and intra-observer agreement: R 0.979, p < 0.01, R 0.946, p < 0.01 respectively) and concordant with IVP (PLR R 0.831, p < 0.01; CR R 0.879, p < 0.01). Conclusion According to our study, ultrasound pupillometry is a feasible and reliable technique for bedside pupillary function assessment, and is a good alternative to infrared video pupillometry. Moreover, it represents the only way for functional pupillary assessment in patients with periorbital hematoma.

Publisher

Georg Thieme Verlag KG

Subject

Radiology Nuclear Medicine and imaging

Reference22 articles.

1. The Pupil. Anatomy, Physiology and Clinical Applications.

2. Autonomic control of the eye;D H McDougal;Compr Physiol,2015

3. Guidelines for the Management of Severe Traumatic Brain Injury;N Carney;Neurosurgery,2017

4. Fixed and dilated pupils after trauma, stroke, and previous intracranial surgery: management and outcome;H Clusmann;J Neurol Neurosurg Psychiatry,2001

5. Mechanism of opioid-induced pupillary effects;M D Larson;Clin Neurophysiol,2008

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3