Objective Epicutaneo-caval catheters (ECCs) are essential for the care of sick infants who require long-term medical and nutritional management. The aim of this study was to investigate the use of real-time ultrasound as an alternative to X-rays to reduce the incidence of primary malpositions during catheter insertion. Study Design Data on ECCs were retrospectively collected in a tertiary neonatal intensive care unit. Catheter were analyzed considering the tip location technique (standard chest–abdominal radiograph vs real-time ultrasound) Results A total of 248 ECCs were analyzed. Of these, 118 catheters had primary malposition (47.6%). The tip of 165 catheters was assessed using standard chest–abdominal X-rays and 107 (64.8%) were found to be in an inappropriate location. In the group of 83 catheters that were placed using real-time ultrasound for tip location, only 11 catheters (13.2%) had primary malposition. The rate of malposition among the two groups showed a statistically significant difference (p < 0.001). Hypothetically, 300 chest X-rays could have been saved if real-time ultrasound had been used to locate the tip, reducing radiation exposure to infants. Conclusion The use of a real-time ultrasound may be beneficial in reducing primary catheter malpositions compared with conventional radiography. In addition, secondary malpositions and catheter-related complications can be monitored over time. Key Points

Publisher

Georg Thieme Verlag KG

Subject

Obstetrics and Gynecology,Pediatrics, Perinatology and Child Health

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3