Endoscopic ultrasound-guided liver biopsy using a 22-G fine needle biopsy needle: a prospective study

Author:

Hasan Muhammad K.1,Kadkhodayan Kambiz1,Idrisov Evgeny2,Ali Saeed2,Rafiq Ehsan3,Ben-Ami Shor Dana14,Abdel-Jalil Ala1,Navaneethan Uday1,Bang Ji1,Varadarajulu Shyam1,Hawes Robert1,Pernicone Peter5

Affiliation:

1. Center for Interventional Endoscopy, AdventHealth Orlando, Florida, USA

2. Department of Internal Medicine, AdventHealth Orlando, Florida, USA

3. Department of Gastroenterology and Hepatology, AdventHealth Orlando, Florida, USA

4. Sackler Faculty of Medicine, Tel-Aviv University, Tel-Aviv, Israel

5. Department of Pathology, AdventHealth Orlando, Florida, USA

Abstract

Abstract Background Endoscopic ultrasound-guided liver biopsy (EUS-LB) using a 19-gauge (19-G) EUS needle is becoming increasingly popular. We evaluated the efficacy and safety of a 22-G EUS fine needle biopsy (FNB) needle for performing EUS-LB. Methods Patients referred for evaluation of elevated liver enzymes and without obstructive disease requiring endoscopic retrograde cholangiopancreatography (ERCP) were included. Using a 22-G FNB needle, two passes were made from the left lobe and one from the right. The main outcome measure was adequacy of the specimen for histology interpretation, and the secondary outcome was the safety of EUS-guided liver biopsy with a 22-G FNB needle. Patients were followed for post-procedure complications for 30 days. Results 40 patients (median age 61 years; 26 women) underwent EUS-LB. Analyzing by needle passes, the median longest core fragment was 12 mm (1st quartile – 3rd quartile 10 mm – 16.25 mm, interquartile range [IQR] 6.25 mm) from the left lobe and 11 mm (10 mm – 15.75 mm, IQR 5.75 mm) from the right lobe. The median cumulative core length per patient was 55 mm (44.5 mm – 68 mm, IQR 23.5 mm). The median cumulative number of complete portal triads (CPTs) per patient was 42 (28.5 – 53, IQR 24.5). The specimen was considered adequate in all 40 patients (100 %). Self-limiting abdominal pain was reported in 6 patients (15 %). Conclusions EUS-LB using a 22-G FNB needle is a safe and viable alternative to the use of larger gauge needles, yielding adequate tissue for evaluation of parenchymal disease in 100 % of the patients.

Publisher

Georg Thieme Verlag KG

Subject

Gastroenterology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3