Use of ambient lighting during colonoscopy and its effect on adenoma detection rate and eye fatigue: results of a pilot study

Author:

Hoff Ryan T.1,Mazulis Andrew1,Doniparthi Meghana1,Munis Assad1,Rivelli Anne2,Lakha Asif1,Ehrenpreis Eli13

Affiliation:

1. Advocate Lutheran General Hospital – Medicine, Park Ridge, Illinois, United States

2. Advocate Lutheran General Hospital – Russell Research Institute, Park Ridge, Illinois, United States

3. Rosalind Franklin University of Medicine and Science Chicago Medical School – Medicine, North Chicago, Illinois, United States

Abstract

Abstract Background and study aims Adenoma detection rate (ADR) appears to decrease as the number of consecutive hours performing procedures increases, and eye strain may be a contributing factor. Ambient light may improve symptoms of eye strain, but its effects have yet to be explored in the field of gastroenterology. We aim to determine if using ambient lighting during screening colonoscopy will maintain ADRs and improve eye strain symptoms compared with low lighting. Methods At a single center, retrospective data were collected on colonoscopies performed under low lighting and compared to prospective data collected on colonoscopies with ambient lighting. Eye fatigue surveys were completed by gastroenterologists. Satisfaction surveys were completed by physicians and staff. Results Of 498 low light and 611 ambient light cases, 172 and 220 adenomas were detected, respectively (P = 0.611). Under low lighting, the ADR decreased 5.6 % from first to last case of the day (P = 0.2658). With ambient lighting, the ADR increased by 2.80 % (P = 0.5445). The difference in the overall change in ADR between first and last cases with ambient light versus low light was statistically significant (8.40 % total unit change, P = 0.01). The average eye strain scores were 8.12 with low light, and 5.63 with ambient light (P = 0.3341). Conclusions Performing screening colonoscopies with ambient light may improve the differential change in ADR that occurs from the beginning to the end of the day. This improvement in ADR may be related to improvement in operator fatigue. The effect of ambient light on eye strain is unclear. Further investigation is warranted on the impact of ambient light on symptoms of eye strain and ADR.

Publisher

Georg Thieme Verlag KG

Subject

Gastroenterology,Medicine (miscellaneous)

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Ambient light intensity affecting ultrasound operator detection of liver lesions in cine-clips;Radiography;2024-07

2. Review on Signal Generation for Neurofeedback;2022 10th International Conference on Cyber and IT Service Management (CITSM);2022-09-20

3. Measuring and Improving Quality of Colonoscopy for Colorectal Cancer Screening;Techniques and Innovations in Gastrointestinal Endoscopy;2021-11

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3