Abstract

Abstract Objective The objectives of this study were to validate a finite element model of the equine distal limb transfixation cast and to determine the effect of six transcortical pin parameters on bone–pin interface (BPI) stresses in the third metacarpal bone. Study Design A transfixation cast finite element model was developed from a computed tomography scan of the third metacarpal bone and modelled pin elements. The model was validated by comparing strain measured around a 6.3-mm transfixation pin in the third metacarpal bone with the finite element model. The pin parameters of diameter, number, location, spacing, orientation and material were evaluated by comparing a variety of pin configurations within the model. Results Pin diameter and number had the greatest impact on BPI stress. Increasing the diameter and number of pins resulted in lower BPI stresses. Diaphyseal pin location and stainless-steel pins had lower BPI stresses than metaphyseal location and titanium alloy pins, respectively. Offset pin orientation and pin spacing had minimal impact on BPI stresses during axial loading. Conclusion The results provide evidence that diameter and number are the main pin parameters affecting BPI stress in an equine distal limb transfixation cast. Configurations of various pin size and number may be proposed to reduce BPI stresses and minimize the risk of pin related complications. Further refinement of these models will be required to optimize pin configurations to account for pin hole size and its impact on overall bone strength.

Funder

Total Wagers Tax

Publisher

Georg Thieme Verlag KG

Subject

General Veterinary,Animal Science and Zoology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3