Abstract Background The masking-level difference (MLD) can be measured via voluntary behavioral responses (voluntary behavioral MLD [vMLD]) and/or via electrophysiological cortical auditory evoked potentials (CAEPs; electrophysiological MLD [eMLD]). It may be possible to enhance the ecologic validity of the MLD by using nonsense-syllable speech stimuli. Purpose The aim of this study is to determine the feasibility of measuring both the vMLD and eMLD with speech stimuli. The study also investigates whether certain nonsense-syllable stimuli (/α/, /dα/, /di/, /tα/, /wα/) may be more useful than others in measuring both the vMLD and eMLD. Research Design This is a descriptive feasibility pilot study. Study Sample Seventeen young adults (age range 19–26 years; 15 women) with hearing thresholds of 0.25–8.0 kHz ≤ 25 dB HL, bilaterally, were recruited. Data Collection and Analysis Behavioral and electrophysiological MLDs were measured with similar methods. The MLD was defined as SoNo – SπNo thresholds. Stimuli were natural-sounding nonsense syllables (/α/, /dα/, /di/, /tα/, /wα/), which were presented in 65 dB HL continuous speech-weighted noise. The eMLD was measured with the CAEP P2. Group means, standard deviations, and distributions were presented. The feasibility of using nonsense syllables was evaluated by considering whether measurable vMLDs and eMLDs were produced. Useful nonsense syllables produced vMLDs and eMLDs with (1) comparatively large mean magnitudes, (2) few negligible MLDs, and (3) distributions with adequate spread and few extreme values. Results The stimuli /α/ (6.0 [1.9]) and /wα/ (7.5 [1.3]) produced vMLDs with the highest average magnitudes, with no vMLDs of 0 dB and with adequate spread. The stimulus /α/ produced eMLDs with the highest average magnitude (9.6 [2.8]), no eMLDs of 0 dB and adequate spread, whereas the stimulus /wα/ produced eMLDs with an adequate magnitude (6.9 [3.9]), no MLDs of 0 dB, but with a right-skewed distribution and an extreme value. The other stimuli produced vMLDs with low mean magnitudes and several vMLDs of 0 dB. Conclusion These pilot data support the feasibility of using nonsense syllables to record vMLDs and eMLDs. The stimulus /α/ appeared most useful for both behavioral and electrophysiological modalities. Differences in MLDs across modalities may be attributed to low-level audibility of some high-frequency components of the stimuli.

Publisher

Georg Thieme Verlag KG

Reference22 articles.

1. The influence of interaural phase on interaural summation and inhibition;I J Hirsh;J Acoust Soc Am,1948

2. The influence of interaural phase relations upon the masking of speech by white noise;J CR Licklider;J Acoust Soc,1948

3. Effect of peripheral hearing loss on the masking level difference;J Jerger;Arch Otolaryngol,1984

4. Effects of noise bandwidth on the late-potential masking level difference;C G Fowler;Electroencephalogr Clin Neurophysiol,1992

5. Phase effects on the middle and late auditory evoked potentials;C G Fowler;J Am Acad Audiol,1996

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3