Performance of portable objective wound assessment tools: a systematic review

Author:

Tan Poh12,Basonbul Razan A3,Lim Joanne4,Moiemen Naiem12

Affiliation:

1. Burns and Plastics Department, University Hospitals Birmingham NHS Foundation Trust, Queen Elizabeth Medical Centre, Birmingham, UK

2. The Scar Free Foundation Centre for Burns Research, University Hospital Birmingham Foundation Trust, Birmingham, UK

3. Department of Otolaryngology, Head and Neck Surgery, Faculty of Medicine in Rabigh, King Abdulaziz University, Jeddah, Saudi Arabia

4. Department of Obstetrics and Gynaecology, Royal Victoria Infirmary, Queen Victoria Road, Newcastle upon Tyne, UK

Abstract

Objective: Accurate wound assessment is crucial for determining the progression of healing and guides treatment strategies. Portable wound assessment devices can be useful in providing an accurate evaluation in the community where most cases are treated. The objective of this review was to compare the performance of various portable wound assessment techniques used for wound healing assessment described in the literature. Method: In April 2020, electronic databases were searched, using appropriate search terms, for all available publications on the use of portable wound assessment devices on human and artificial wounds. The primary outcome was the reliability and reproducibility of measurement while the secondary outcome was the feasibility of the instrument. All studies underwent quality assessment of diagnostic accuracy studies (QUADAS) to examine the quality of data. Results: A total of 129 articles were identified and 24 were included in the final review; 17 articles discussed two-dimensional (2D) devices; three articles discussed three-dimensional (3D) devices; and four articles discussed application-based devices. Most studies (n=8) reported on a 2D device that had an ICC of 0.92–0.99 for area measurement and a coefficient of variance of 3.1% with an error of 2.3% in human wounds and 1.55-3.7% in artificial wounds. The inter/intra observer reliability was 0.998 and 0.985, respectively with a scan time of two minutes per wound. The median QUADAS score was 12. Conclusion: Based on the presented evidence, 2D-based portable wound assessment devices were the most studied and demonstrated good performance. Further studies are required for 3D and application-based measurement instruments.

Publisher

Mark Allen Group

Subject

Nursing (miscellaneous),Fundamentals and skills

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3