Safety and efficacy of low-energy cardioversion of 500 patients using two different techniques

Author:

Andraghetti A.1,Scalese M.1

Affiliation:

1. Medical PATH Milan, Italy

Abstract

Abstract Aim To present some safety and efficacy issues of low-energy internal cardioversion of chronic atrial fibrillation from 500 consecutive procedures performed with two different techniques, using either two single-coil catheters, or a single twin-coil catheter. Methods and Results Low-energy internal cardioversion was carried out in 368 patients by means of two defibrillation catheters: the former was positioned in the right atrium and the latter either in the left pulmonary artery (212 patients), or in the distal coronary sinus (156 patients). In the remaining 132 patients, a single twin-coil catheter was positioned with the distal coil either in the pulmonary artery (75 patients) or in the coronary sinus (57 patients), while the proximal coil was in the right atrium. The external defibrillator delivered truncated biphasic shocks (6/6 ms, tilt 50%), with a voltage of 10–400 V. In 283 patients (57%) external cardioversion had been unsuccessfully tried before low-energy internal cardioversion. After a total of 1118 shocks, the overall success rate was 92·2% (91·3% with two catheters and 94·7% with the single catheter); the success rate was 93·4 and 91·3% with the coronary sinus and the pulmonary artery approach, respectively. The mean energy used was 6·5±3·4 J (voltage: 320±45 V); no difference was found between the twin catheter (6·3±3·1 J) and the single catheter approach (6·9±3·7 J), while the coronary sinus configuration required a significantly lower energy than the pulmonary artery configuration (5·6±2·9 vs 7·2±3·8 J, P<0·05). The duration of the current atrial fibrillation episode was the only clinical characteristic statistically different between the 461 successfully cardioverted patients and the 39 failures (295 vs 727 days, P<0·01). No complication was recorded during or after the delivery of the therapy; no procedure had to be terminated because of patient's intolerance. Conclusions Low-energy internal cardioversion is a safe and effective procedure for converting chronic atrial fibrillation, confirmed by this large multicentre experience. The newly available twin-coil catheter seems to achieve a slightly better success rate compared with the traditional two-catheter technique, and is associated with the same safety profile.

Publisher

Oxford University Press (OUP)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Reference21 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3