A Comparative Evaluation of the Sensitivity of the L.E. Cell Test Performed Simultaneously by Different Methods

Author:

DUBOIS EDMUND L.1,FREEMAN VIVIAN1

Affiliation:

1. Department of Internal Medicine, University of Southern California School of Medicine and the Los Angeles County General Hospital, Los Angeles, California.

Abstract

Abstract 1) A group of at least three types of L.E. cell tests should be performed in order to adequately screen strongly suspected cases of SLE. This battery consists of the sieved two hour clot, the Snapper-Nathan ring method and the Zinkham-Conley rotary glass bead technic. Utilizing these three methods in studying a group of 47 proven cases of SLE both treated and untreated, 63 batteries were performed. In 42 of these batteries there was at least one positive test. In 5 batteries only the rotary method was positive, in 4 the clotted method and in 2 the ring method. The largest numbers of L.E. cells and hematoxylin bodies were found by the rotary method. If only one test is to be performed this latter technic is the method of choice. 2) The use of excessive amounts of heparin over 0.75 mg./10 cc. of blood resulted in a depression of the L.E. phenomenon. The technic of adding "small amounts" of heparin to blood or "heparinizing a syringe" to draw specimens for L.E. studies is to be avoided. 3) The explanation for the augmentation of the L.E. phenomenon by clotting or rotation with glass beads seemed to be the production of leukocyte trauma by either method. This explained the poor results obtained when the clotted blood specimen is broken up with wooden applicator sticks rather than macerated through a fine sieve. The clotting mechanism itself probably has little to do with the increased numbers of L.E. cells. 4) With adequate treatment the L.E. cells disappeared in many patients. Forty patients with positive L.E. cell tests treated two months or more had a simultaneous battery performed on them as described above. All the tests were negative in eighteen patients, seven patients had fewer than 5 L.E. cells per 500 leukocytes and fifteen patients had more than that number.

Publisher

American Society of Hematology

Subject

Cell Biology,Hematology,Immunology,Biochemistry

Cited by 25 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司