Usefulness of combined handheld ultrasound and fluoroscopy-guided injection in adhesive capsulitis of the shoulder: A prospective, randomized single blind-pilot study

Author:

Park Ki Deok1,Ryu Jeong Won2,Cho Kyoung Rai3,Park Yongbum41,Chung Wook-Jin51

Affiliation:

1. Department of Rehabilitation Medicine, Gil Medical Center, Gachon University College of Medicine, Incheon, Korea

2. Advanced Medical Technology Laboratory, Healcerion Co., Ltd., Seoul, Korea

3. Department of Otorhinolaryngology-Head and Neck Surgery, Sanggye Paik Hospital, Inje University College of Medicine, Seoul, Korea

4. Department of Cardiovascular Medicine, Gachon University Gil Medical Center, Gachon Cardiovascular Research Institute, Gachon University College of Medicine, Incheon, Korea

5. Department of Physical Medicine and Rehabilitation, Sanggye Paik Hospital, Inje University College of Medicine, Seoul, Korea

Abstract

BACKGROUND: Ultrasound is increasingly being utilized in the diagnosis and treatment of adhesive capsulitis. OBJECTIVE: To compare the therapeutic effects and advantages of combined handheld ultrasound and fluoroscopy-guided intra-articular corticosteroid injection with those of conventional ultrasound-guided corticosteroid injection in adhesive capsulitis of the shoulder. METHODS: A total of 39 patients diagnosed with adhesive capsulitis of the shoulder were randomly assigned into two groups. Group A patients (n= 19) underwent combined handheld ultrasound and fluoroscopy-guided corticosteroid injection and group B patients (n= 20) underwent conventional ultrasound-guided corticosteroid injection to the intra-articular space of the shoulder twice. Treatment efficacy was assessed at 2 and 6 weeks after the final injection, based on the verbal numeric pain scale, Shoulder Pain and Disability Index, and range of motion. Secondary outcome measures were the accuracy and procedure time. RESULTS: Both injection methods were effective in the treatment of adhesive capsulitis. No significant differences in treatment efficacy and injection accuracy were observed between the two groups (p> 0.05). CONCLUSIONS: This study showed no statistical differences in treatment efficacy between 2 groups. However, the combined use of ultrasound and fluoroscopy can increase the accuracy of injection compared with conventional ultrasound alone.

Publisher

IOS Press

Subject

Rehabilitation,Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3