Comparative accuracy of a shoulder range motion measurement sensor and Vicon 3D motion capture for shoulder abduction in frozen shoulder

Author:

Park Chanhee12,An Yeongsang2,Yoon Hyunsik3,Park Ilbong4,Kim Kyoungtae5,Kim Chungyoo6,Cha Youngjoo4

Affiliation:

1. Department of Physical Therapy, Yonsei University, Wonju, Korea

2. Funrehab Co., Ltd, Daejoeon, Korea

3. Department of Physical Therapy, Chungnam National University Hospital, Daejeon, Korea

4. Department of Sports Rehabilitation, Busan University of Foreign Studies, Busan, Korea

5. Department of Physical Therapy, Cheju Halla University, Jeju, Korea

6. Department of Rehabilitation Medicine, Busan St. Mary’s Hospital, Busan, Korea

Abstract

BACKGROUND: Although patients with frozen shoulders have the range of motion (ROM) of their shoulder’s abduction movements measured at hospital and the physical therapy visits, multiple visits to check for progress is often difficult. Thus, we developed an artificial intelligence-based image recognition detectable sensor (AIRDS) intended for easy use at home. OBJECTIVE: The purpose of this study was to determine the accuracy of a sensor (AIRDS) measuring shoulder abduction angle, thus offering a valid and feasible system for monitoring patients with frozen shoulder. METHODS: Ten patients with frozen shoulder (5 males, 5 females) performed shoulder joint movements while being measured with the AIRDS system and the 3-dimensional Vicon system. The measure of the outcome included the linear regression of the shoulder abduction joint kinematics. RESULTS: Linear regression analysis of the AIRDS system and the Vicon system demonstrated a significant correlation coefficient of R2= 0.9979 (P< 0.05). CONCLUSIONS: Our results provide novel, promising evidence that AIRDS can accurately measure the timing and total spatial characteristics of clinical movements. AIRDS is designed to provide real-time ROM measurements for joint mobility using artificial intelligence instead of the judgement of the physical therapist.

Publisher

IOS Press

Subject

Health Informatics,Biomedical Engineering,Information Systems,Biomaterials,Bioengineering,Biophysics

Reference14 articles.

1. Frozen shoulder syndrome;Sharma;International Orthopaedics.,1993

2. The pathology of frozen shoulder. A dupuytren-like disease. The journal of bone and joint surgery;Bunker;British volume.,1995

3. The frozen shoulder. Diagnosis and management;Neviaser;Clinical Orthopaedics and Related Research.,1987

4. Effects of whole-body cryotherapy in the management of adhesive capsulitis of the shoulder;Ma;Archives of Physical Medicine and Rehabilitation.,2013

5. Efficacies of corticosteroid injection at different sites of the shoulder for the treatment of adhesive capsulitis;Shin;Journal of Shoulder and Elbow Surgery.,2013

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3