Reducing amount of contrast agent after compression of right brachial artery using a blood pressure cuff in computed tomography cerebrovascular angiography

Author:

Kim Gyeong Rip1,Kim Sungho2,Sung Soon Ki1,Kim Chang Hyeun1,Lee Sang Bong3,Yoo Jang Seon4,Kwak Jong Hyeok4

Affiliation:

1. Department of Neurosurgery, Pusan National University Yang-san Hospital, Pusan National University School of Medicine, Yang-san, Korea

2. Department of Biomedical Engineering, Ulsan National Institute of Science and Technology, Ulsan, Korea

3. Department of Hospital and Social cooperation, Good Gangan Hospital, Busan, Korea

4. Department of Radiology, Pusan National University Yang-san Hospital, Yang-san, Korea

Abstract

OBJECTIVE: To invastgate feasibility of low-dose contrast agent in cerebral computed tomography angiography (CTA) to alleviate side effects. METHOD: Siemens’ Somatom Definition AS+CT scanner, Heine’s blood pressure monitor G7-M237 (BP cuff) and Ultravist contrast agent (370 mg Iodine/ml) are used. CTA is acquired using following scan parameters including slice thickness of 1mm, image acquisition parameters of 128×0.6 mm, pitch size of 0.8 mm, 175 effective mAs, 120 kVp tube voltage, scan delay time of 3 seconds, and the scan time of 4 seconds. This study is conducted by securing the IV route in the left antecubital vein before injection of contrast agent, wrapping BP cuff around the branchial artery of the opposite right arm after setting the pressure to 200 mmHg. Then, the injection rate of the contrast agent is fixed at 4.5 cc/sec and contrast agent was injected in three different amounts (70, 80, and 100 cc). Bp cuff is released from this moment when HU value reachs 100. RESULT: In this study, the mean HU values measured from common carotid artery are 412.45±5.89 when injecting 80cc contrast agent and using BP cuff and 399.64±5.51 when injecting 100 cc contrast agenet and not using BP cuff, respectively. In middle cerebral artery M1, the mean HU values are 325.23±38.29 when injecting 80cc contrast agent and using BP cuff and 325.00±30.63 when injecting 100cc contrast agent blood and not using pressure cuff, respectively. Difference of mean HU values is not statistically significant (p > 0.05) with and without using BP cuff. CONCLUSION: This study demonstrates that reducing amount of contrast agent is possible when the right brachial artery is compressed using BP cuff. Study results indicate that reducing 20% injection of contrast agent in CT cerebrovascular angiography can still yield comparable imaging results with conventional contrast angent usage, which implies that less side effects are expected with a contrast agent injection. Thus, this study can serve as a reference for potential reducing side effect during CT cerebrovascular angiography.

Publisher

IOS Press

Subject

Electrical and Electronic Engineering,Condensed Matter Physics,Radiology, Nuclear Medicine and imaging,Instrumentation,Radiation

Reference17 articles.

1. Cerebral computed tomography angiography using a low tube voltage (80kVp) and a moderate concentration of iodine contrast material: a quantitative and qualitative comparison with conventional computed tomography angiography;Cho;Investigative Radiology,2012

2. Antibiofouling polymer-coated gold nanoparticles as a contrast agent for in vivo X-ray computed tomography imaging;Kim;Journal of the American Chemical Society,2007

3. Metrizamide-phenothiazine interaction: report of a case with seizures following myelography;Hindmarsh;Acta Radiologica. Diagnosis,1975

4. Trimetazidine and the contractile response of dysfunctional myocardium in ischaemic cardiomyopathy, V;Belardinelli;Revista Portuguesa de Cardiologia,2000

5. Zhou Y. , Chen M.N. and Liu Y. , Use of low-dose contrast agent in cerebral angiography produces high-quality diagnostic images, International Journal of Clinical and Experimental Misedicine 7 (1331).

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3