Set-up errors of the neck are underestimated using the overall registration frame of head and neck in IMRT for NPC

Author:

Xu Junjie1,Wang Tong1,Luo Yu1,Shang Lintao1,Mai Xiuying1,Ruan Junjie1,Pan Xiaofen2,Chi Feng1

Affiliation:

1. State Key Laboratory of Oncology in South China, Sun Yat-sen University Cancer Center, Guangzhou, China

2. Department of Oncology, The Seventh Affiliated Hospital, Sun Yat-sen University, Shenzhen, China

Abstract

Background: There is no standardized registration frame of cone beam CT (CBCT) in intensity modulated radiotherapy (IMRT) for nasopharyngeal carcinoma (NPC). The overall registration frame that covers the whole head and neck is the most commonly used CBCT registration frame for NPC patients in IMRT. Objective: To compare the set-up errors using different registration frames of CBCT for NPC to assess the set-up errors for different region of the commonly used clinical overall registration frame. Methods: 294 CBCT images of 59 NPC patients were collected. Four registration frames were used for matching. The set-up errors were obtained using an automatic matching algorithm and then compared. The expansion margin from the clinical target volume (CTV) to the planned target volume (PTV) in the four groups was also calculated. Results: The average range of the isocenter translation and rotation errors of four registration frames are 0.89∼2.41 mm and 0.49∼1.53°, respectively, which results in a significant difference in the set-up errors (p < 0.05). The set-up errors obtained from the overall frame are smaller than those obtained from the head, upper neck, and lower neck frames. The margin ranges of the overall, head, upper neck, and lower neck frames in three translation directions are 1.49∼2.39 mm, 1.92∼2.45 mm, 1.86∼3.54 mm and 3.02∼4.78 mm, respectively. The expansion margins calculated from the overall frame are not enough, especially for the lower neck. Conclusion: Set-up errors of the neck are underestimated by the overall registration frame. Thus, it is important to improve the position immobilization of the neck, especially the lower neck. The margin of the target volume of the head and neck region should be expanded separately if circumstances permit.

Publisher

IOS Press

Subject

Electrical and Electronic Engineering,Condensed Matter Physics,Radiology, Nuclear Medicine and imaging,Instrumentation,Radiation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3