Pitfalls and strategies of Sonazoid enhanced ultrasonography in differentiating metastatic and benign hepatic lesions

Author:

Zhang Wei1,Liu Yilun1,Wu Qiong1,Wei Xiaoer2,Liu Beibei2,Jiao Qiong3,Zhang Rui4,Hu Bing15,Li Yi1,Ying Tao15

Affiliation:

1. Department of Ultrasound in Medicine, Shanghai Sixth People’s Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China

2. Institute of Diagnostic and Interventional Radiology, Shanghai Sixth People’s Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China

3. Department of Pathology, Shanghai Sixth People’s Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China

4. Department of Obstetrics and Gynecology, Shanghai Sixth People’s Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China

5. Shanghai Institute of Ultrasound in Medicine, Shanghai, China

Abstract

OBJECTIVE: This article aims to clarify pitfalls and find strategies for the detecting and diagnosing hyperechoic liver metastases (LMs) using Sonazoid-contrast enhanced ultrasonography (Sonazoid-CEUS). METHODS: This study was a prospective self-controlled study. Patients with hepatic lesions suspected as LMs or benign lesions were included in the study. Baseline ultrasonography (BUS) and Sonazoid-CEUS were performed on every patient. Characteristics of LMs and benign nodules were compared by chi-square test and fisher test. Factors influenced the CEUS were demonstrated by univariate analysis and multivariate logistic regression analysis. RESULTS: 54 patients were included in this study. CEUS found additional 75 LMs from 19 patients in Kupffer phase. We found hyperechoic focal liver lesions and deep seated in liver are main confounding factors in CEUS diagnosis. Sensitivity would be improved from 16.67% to 78.57%, negative predictive value (NPV) would be improved from 28.57% to 76.92% and accuracy would be improved from 37.5% to 87.50% when using rapid “wash-in” and “wash-out” as main diagnostic criteria. CONCLUSIONS: Hyperechoic LMs especially deeply seated ones are usually not shown typical “black hole” sign in Kupffer phase. Quickly “wash-in and wash out” shows high accuracy in diagnosing malignant nodules. We highly recommend CEUS as a routing exam to detect and diagnose LMs.

Publisher

IOS Press

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine,Hematology,Physiology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3