Recombinant urokinase for restoration of patency in occluded central venous access devices

Author:

Deitcher Steven,Mullane Kathleen,Jaff Michael,Firszt Carolyn,Schulz Gregory,Schuerr Debra,Schwartz Lewis,Mouginis Tamyra,Barton R.,Haire William

Abstract

SummaryThe interval occlusion of central venous access devices (CVADs) remains a significant clinical problem, often requiring re-intervention for catheter exchange or replacement.The purpose of this Phase 3, multi-center, double-blinded study was to test the hypothesis that instillation of recombinant urokinase (r-UK) 5000 IU/ml is superior to placebo in restoring total catheter patency to an unselected cohort of occluded CVADs. After obtaining informed consent, adult and pediatric patients with occluded, non-hemodialysis CVADs of any duration or type were randomized (2 : 1) to receive either r-UK 5000 IU/ml or placebo instilled into all occluded lumens of their catheter. Catheter function was assessed at 5, 15 and 30 min after the first instillation. If the catheter remained occluded after 30 min, a second dose was instilled with repeat assessments at 5, 15 and 30 min.The primary efficacy variable was the restoration of catheter function to all treated lumens (i.e., total catheter patency) after one or two instillations. Catheters that were not successfully recanalized after two instillations were allowed to receive up to two instillations of open-label r-UK administered in the same manner.The primary safety variable was the occurrence of hemorrhagic and non-hemorrhagic events within 72 hr after instillation. A total of 180 patients were enrolled at 43 sites in the United States and Canada. Most patients were adults, although 20% were ≤18 years of age. CVAD types included totally implanted subcutaneous ports (45%), PICC lines (26%), non-tunneled percutaneous catheters (18%), and tunneled percutaneous catheters (10%). All CVADs were occluded by virtue of their inability to withdraw blood (withdrawal occlusion). Additionally, 32% of catheters were completely dysfunctional as blood could not be withdrawn and fluids could not be infused (total occlusion). Analysis of the results showed that r-UK was significantly better than placebo in restoring catheter function (54% versus 30%, p = 0.002). There were no major hemorrhagic events within 72 hr after up to four r-UK instillations, and the incidence of non-hemorrhagic events was similar among the r-UK and placebo groups. In conclusion, r-UK is superior to placebo in restoring total catheter patency to occluded CVADs. In patients with occluded CVADs, intra-catheter thrombolysis can restore patency and may obviate the need for catheter replacement.

Funder

Abbott Laboratories, Illinois USA

Publisher

Georg Thieme Verlag KG

Subject

Hematology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3