Automated devices for identifying peripheral arterial disease in people with leg ulceration: an evidence synthesis and cost-effectiveness analysis

Author:

Boyers Dwayne1ORCID,Cruickshank Moira2ORCID,Aucott Lorna2ORCID,Kennedy Charlotte1ORCID,Manson Paul2ORCID,Bachoo Paul3ORCID,Brazzelli Miriam1ORCID

Affiliation:

1. Health Economics Research Unit, University of Aberdeen, Aberdeen, UK

2. Health Services Research Unit, University of Aberdeen, Aberdeen, UK

3. NHS Grampian, Aberdeen, UK

Abstract

Abstract Background Peripheral artery disease is a common condition caused by narrowing/blockage of the arteries, resulting in reduced blood supply. Peripheral artery disease is associated with an increased risk of vascular complications, but early treatment reduces mortality and morbidity. Leg ulcers are long-lasting wounds, usually treated by compression therapy. Compression therapy is not suitable for people with peripheral artery disease, as it can affect the arterial blood supply. In clinical practice, people with peripheral artery disease are identified by measurement of the ankle–brachial pressure index using a sphygmomanometer and manual Doppler device. However, this method can be uncomfortable for people with leg ulcers and automated devices have been proposed as a more acceptable alternative. The objective of this appraisal was to summarise the clinical and cost-effectiveness evidence on the use of automated devices to detect peripheral artery disease in people with leg ulcers. Methods Clinical effectiveness To identify reports of relevant studies, we searched major electronic databases and scrutinised the information supplied by the manufacturers of the automated devices under investigation. Due to the lack of evidence on people with leg ulcers, we considered evidence from studies of any design assessing automated devices versus an acceptable reference device in any population receiving ankle–brachial pressure index assessment. We summarised information on diagnostic accuracy of the automated devices and level of agreement with the reference device. For each device, when data permit, we pooled data across studies by conducting random-effects meta-analyses using a Hierarchical Summary Receiving Operating Characteristics model. Cost-effectiveness An economic model comprising a decision tree (24 weeks) and Markov models to capture lifetime costs and quality-adjusted life-years associated with venous, arterial and mixed aetiology disease in leg ulcer patients. Analyses were conducted from a United Kingdom National Health Service and Personal Social Services perspective. Costs and quality-adjusted life-years were discounted at 3.5% per year. Deterministic and several probabilistic analyses were used to capture uncertainty surrounding a range of optimistic and pessimistic assumptions about the impact of automated tests on health outcomes (ulcer healing and requirement for invasive management of arterial disease). Results Clinical effectiveness From the 116 records retrieved by the electronic searches, we included 24 studies evaluating five devices (BlueDop Vascular Expert, BOSO ABI-System 100, Dopplex Ability, MESI ankle–brachial pressure index MD and WatchBP Office ABI). Two studies assessing people with leg ulcers found that automated devices often gave higher ankle–brachial pressure index readings than manual Doppler (underestimation of arterial disease). In the 22 studies involving people without leg ulcers, automated devices generally demonstrated good specificity and moderate specificity. Meta-analysis of 12 studies showed a pooled sensitivity of 64% (95% confidence interval 57% to 71%) and a pooled specificity of 96% (95% confidence interval 92% to 98%) for detection of peripheral artery disease. Cost-effectiveness Automated devices cost less than manual Doppler to deliver. However, increased risks of invasive treatment requirements for inappropriately compressed arterial/mixed ulcers due to false-negative results, and increased healing times due to delayed compression of false-positive test results mean that in most scenarios manual Doppler was less costly and had slightly higher quality-adjusted life-years than automated devices. Results are highly uncertain, dependent on many assumptions and should be interpreted cautiously. Limitations and conclusions The limited evidence identified for each automated device, especially in people with leg ulcers, and its clinical heterogeneity precludes any firm conclusions on the diagnostic performance and cost-effectiveness of these devices in clinical practice. Study registration This study is registered as PROSPERO CRD42022327588. Funding This award was funded by the National Institute for Health and Care Research (NIHR) Evidence Synthesis programme (NIHR award ref: NIHR135478) and is published in full in Health Technology Assessment; Vol. 28, No. 37. See the NIHR Funding and Awards website for further award information.

Funder

Health Technology Assessment programme

Publisher

National Institute for Health and Care Research

Reference118 articles.

1. Lipid-lowering for peripheral arterial disease of the lower limb;Aung;Cochrane Database Syst Rev,2007

2. Peripheral artery disease;Morley;BMJ,2018

3. Inter-society consensus for the management of peripheral arterial disease (TASC II);Norgren;J Vasc Surg,2007

4. Incidence, natural history and cardiovascular events in symptomatic and asymptomatic peripheral arterial disease in the general population;Leng;Int J Epidemiol,1996

5. Compression for preventing recurrence of venous ulcers;Nelson;Cochrane Database Syst Rev,2014

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3