Analytical Validation of the Oncotype DX Genomic Diagnostic Test for Recurrence Prognosis and Therapeutic Response Prediction in Node-Negative, Estrogen Receptor–Positive Breast Cancer

Author:

Cronin Maureen,Sangli Chithra1,Liu Mei-Lan1,Pho Mylan1,Dutta Debjani1,Nguyen Anhthu1,Jeong Jennie1,Wu Jenny1,Langone Kim Clark1,Watson Drew1

Affiliation:

1. Genomic Health, Inc., Redwood City, CA

Abstract

Abstract Background: Oncotype DX™ is a clinically validated, high-complexity, multianalyte reverse transcription–PCR genomic test that predicts the likelihood of breast cancer recurrence in early-stage, node-negative, estrogen receptor–positive breast cancer. The Recurrence Score™ (RS) provides a more accurate, reproducible measure of breast cancer aggressiveness and therapeutic responsiveness than standard measures. Individualized patient management requires strict performance criteria for clinical laboratory tests. We therefore investigated the analytical performance of the assay. Methods: Assays used a pooled RNA sample from fixed paraffin-embedded tissues to evaluate the analytical performance of a 21-gene panel with respect to amplification efficiency, precision, linearity, and dynamic range, as well as limits of detection and quantification. Performance variables were estimated from assays carried out with sample dilutions. In addition, individual patient samples were used to test the optimized assay for reproducibility and sources of imprecision. Results: Assay results defined acceptable operational performance ranges, including an estimated maximum deviation from linearity of <1 cycle threshold (CT) units over a ≥2000-fold range of RNA concentrations, with a mean quantification bias of 0.3% and CVs of 3.2%–5.7%. An analysis of study design showed that assay imprecision contributed by instrument, operator, reagent, and day-to-day baseline variation was low, with SDs of <0.5 CT. Conclusion: The analytical and operational performance specifications defined for the Oncotype DX assay allow the reporting of quantitative RS values for individual patients with an SD within 2 RS units on a 100-unit scale.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry, medical,Clinical Biochemistry

Cited by 291 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3