Harmonization of Measurement Results of the Alcohol Biomarker Carbohydrate-Deficient Transferrin by Use of the Toolbox of Technical Procedures of the International Consortium for Harmonization of Clinical Laboratory Results

Author:

Weykamp Cas1,Wielders Jos2,Helander Anders3,Anton Raymond F4,Bianchi Vincenza5,Jeppsson Jan-Olof6,Siebelder Carla1,Whitfield John B7,Schellenberg François8

Affiliation:

1. Department of Clinical Chemistry, Queen Beatrix Hospital, Winterswijk, the Netherlands

2. Department of Clinical Chemistry, Meander Medical Center, Amersfoort, the Netherlands

3. Department of Laboratory Medicine, Karolinska Institutet, and Karolinska University Laboratory, Clinical Chemistry, Stockholm, Sweden

4. The Center for Drug and Alcohol Programs, Medical University of South Carolina, Charleston, SC

5. Toxicology Reference Laboratory, SS. Antonio e Biagio Hospital, Alessandria, Italy

6. Department of Laboratory Medicine, Malmö University Hospital, Malmö, Sweden

7. Queensland Institute of Medical Research, Brisbane, Australia

8. Laboratoire de Biochimie, Hôpital Trousseau, Tours, France

Abstract

Abstract BACKGROUND The need for equivalent results of routine measurement procedures for the alcohol biomarker carbohydrate-deficient transferrin (CDT) has been recognized by the IFCC. This article describes a project to harmonize CDT as conducted by an IFCC working group initiated for this purpose. METHODS We used procedures for achieving harmonization as developed by the Consortium for Harmonization of Clinical Laboratory Results to assess the suitability of a candidate reference measurement procedure (cRMP), candidate reference materials (cRMs), and the success of efforts to achieve harmonization. RESULTS CDT measurement procedures in routine use showed good reproducibility (CV 1.1%–2.8%) and linearity (r > 0.990) with variable slopes (0.766–1.065) and intercepts (−0.34 to 0.92) compared to the cRMP. Heterogeneity after simulated harmonization was 4.7%. cRMs of frozen human native sera demonstrated commutability and 3-year stability for routine measurement procedures. The cRMP provided reproducible value assignment to cRMs with an expanded uncertainty (k = 2) of 0.03% at the 1.2% CDT level and 0.06% at the 4.4% CDT level. Harmonization efforts reduced the intermeasurement CV from 8.8% to 3.4%, allowed 99% recovery of the values assigned with the cRMP, and demonstrated 99% of results within the desirable allowable total error. Harmonization was less successful in samples with low CDT and high trisialotransferrin concentrations. CONCLUSIONS Harmonization of CDT is possible with frozen human native sera as cRMs with values assigned by use of the cRMP. We propose the cRMP as a candidate international conventional reference measurement procedure and cRMs as candidate international calibrators.

Funder

National Institute on Alcohol Abuse and Alcoholism

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3