Characterization of the New Serum Protein Reference Material ERM-DA470k/IFCC: Value Assignment by Immunoassay

Author:

Zegers Ingrid1,Keller Thomas2,Schreiber Wiebke3,Sheldon Joanna4,Albertini Riccardo5,Blirup-Jensen Søren6,Johnson Myron7,Trapmann Stefanie1,Emons Hendrik1,Merlini Giampaolo5,Schimmel Heinz1

Affiliation:

1. Institute for Reference Materials and Measurements (IRMM), Joint Research Centre, European Commission, Geel, Belgium

2. Acomed Statistik, Leipzig, Germany

3. Dade Behring Marburg GmbH, now Siemens Healthcare Diagnostics Products GmbH, Marburg, Germany

4. Protein Reference Unit, St. Georges Hospital, London, UK

5. Biotechnology Research Laboratories, Fondazione IRCCS Policlinico San Matteo and University of Pavia, Italy

6. Lund University Hospital, Lund, Sweden

7. University of North Carolina School of Medicine, Chapel Hill, NC

Abstract

BACKGROUNDThe availability of a suitable matrix reference material is essential for standardization of the immunoassays used to measure serum proteins. The earlier serum protein reference material ERM-DA470 (previously called CRM470), certified in 1993, has led to a high degree of harmonization of the measurement results. A new serum protein material has now been prepared and its suitability in term of homogeneity and stability has been verified; after characterization, the material has been certified as ERM-DA470k/IFCC.METHODSWe characterized the candidate reference material for 14 proteins by applying a protocol that is considered to be a reference measurement procedure, by use of optimized immunoassays. ERM-DA470 was used as a calibrant.RESULTSFor 12 proteins [α2 macroglobulin (A2M), α1 acid glycoprotein (orosomucoid, AAG), α1 antitrypsin (α1-protease inhibitor, AAT), albumin (ALB), complement 3c (C3c), complement 4 (C4), haptoglobin (HPT), IgA, IgG, IgM, transferrin (TRF), and transthyretin (TTR)], the results allowed assignment of certified values in ERM-DA470k/IFCC. For CRP, we observed a bias between the lyophilized and liquid frozen materials, and for CER, the distribution of values was too broad. Therefore, these 2 proteins were not certified in the ERM-DA470k/IFCC. Different value transfer procedures were tested (open and closed procedures) and found to provide equivalent results.CONCLUSIONSA new serum protein reference material has been produced, and values have been successfully assigned for 12 proteins.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

Cited by 68 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献