Measurement of Thyroglobulin by Liquid Chromatography–Tandem Mass Spectrometry in Serum and Plasma in the Presence of Antithyroglobulin Autoantibodies

Author:

Kushnir Mark M12,Rockwood Alan L12,Roberts William L,Abraham Dev3,Hoofnagle Andrew N4,Meikle A Wayne123

Affiliation:

1. ARUP Institute for Clinical and Experimental Pathology, Salt Lake City, UT

2. Departments of Pathology and

3. Medicine, University of Utah, Salt Lake City, UT

4. Departments of Laboratory Medicine and Medicine, University of Washington, Seattle, WA

Abstract

BACKGROUND Measurement of serum thyroglobulin (Tg) is used to monitor patients after treatment for differentiated thyroid carcinoma (TC). Difficulty in using Tg as a biomarker of the recurrence of TC in many patients stems from the presence of endogenous anti-Tg autoantibodies (Tg-AAbs), which can interfere with immunoassays (IAs) and cause false-negative results. METHODS We enriched Tg from serum samples using rabbit polyclonal anti-Tg antiserum and protein precipitation. Unrelated proteins were partially depleted in the process. Enriched proteins were then denatured, reduced, and digested with trypsin after the addition of a winged internal standard peptide. A Tg-specific tryptic peptide was purified by immunoaffinity extraction and analyzed by 2-dimensional LC-MS/MS. Instrument cycle time was 6.5 min per sample. RESULTS The lower limit of quantification was 0.5 ng/mL (0.76 fmol/mL dimer). Total imprecision of triplicate measurements in serum samples over 5 days was <10%. Comparison with a commercial IA using serum samples free of Tg-AAb (n = 73) showed Deming regression, IA = 1.00 * LC-MS/MS − 2.35, r = 0.982, standard error of the estimate (Sy|x) = 9.52. In a set of Tg-AAb–positive samples that tested negative for Tg using IA (n = 71), concentrations determined by LC-MS/MS were ≥0.5 ng/mL in 23% of samples (median 1.2, range 0.7–11 ng/mL). CONCLUSIONS The introduced method has acceptable performance characteristics for use in clinical diagnostic applications. The most substantial disagreement between methods was observed in Tg-AAb–positive samples with concentrations <2 ng/mL (determined with LC-MS/MS). The affinity-assisted enrichment strategy used for Tg in this method should be applicable to other biomarkers that have endogenous autoantibodies.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry, medical,Clinical Biochemistry

Cited by 173 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3