Long-Term Biological Variation of Serum Protein Electrophoresis M-Spike, Urine M-Spike, and Monoclonal Serum Free Light Chain Quantification: Implications for Monitoring Monoclonal Gammopathies

Author:

Katzmann Jerry A12,Snyder Melissa R1,Rajkumar S Vincent12,Kyle Robert A12,Therneau Terry M3,Benson Joanne T3,Dispenzieri Angela12

Affiliation:

1. Division of Clinical Biochemistry & Immunology, Department of Laboratory Medicine & Pathology

2. Division of Hematology, Department of Internal Medicine; and

3. Department of Biomedical Statistics & Informatics, Mayo Clinic, Rochester, MN

Abstract

BACKGROUND We analyzed serial data in patients with clinically stable monoclonal gammopathy to determine the total variation of serum M-spikes [measured with serum protein electrophoresis (SPEP)], urine M-spikes [measured with urine protein electrophoresis (UPEP)], and monoclonal serum free light chain (FLC) concentrations measured with immunoassay. METHODS Patients to be studied were identified by (a) no treatment during the study interval, (b) no change in diagnosis and <5 g/L change in serum M-spike over the course of observation; (c) performance of all 3 tests (SPEP, UPEP, FLC immunoassay) in at least 3 serial samples that were obtained 9 months to 5 years apart; (d) serum M-spike ≥10 g/L, urine M-spike ≥200 mg/24 h, or clonal FLC ≥100 mg/L. The total CV was calculated for each method. RESULTS Among the cohort of 158 patients, 90 had measurable serum M-spikes, 25 had urine M-spikes, and 52 had measurable serum FLC abnormalities. The CVs were calculated for serial SPEP M-spikes (8.1%), UPEP M-spikes (35.8%), and serum FLC concentrations (28.4%). Combining these CVs and the interassay analytical CVs, we calculated the biological CV for the serum M-spike (7.8%), urine M-spike (35.5%), and serum FLC concentration (27.8%). CONCLUSIONS The variations in urine M-spike and serum FLC measurements during patient monitoring are similar and are larger than those for serum M-spikes. In addition, in this group of stable patients, a measurable serum FLC concentration was available twice as often as a measurable urine M-spike.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3