Multiple-Reaction Monitoring–Mass Spectrometric Assays Can Accurately Measure the Relative Protein Abundance in Complex Mixtures

Author:

Hoofnagle Andrew N12,Becker Jessica O1,Oda Michael N3,Cavigiolio Giorgio3,Mayer Philip2,Vaisar Tomas2

Affiliation:

1. Departments of Laboratory Medicine and

2. Medicine, University of Washington, Seattle, WA

3. Children's Hospital and Research Institute, Oakland, CA

Abstract

Abstract BACKGROUND Mass spectrometric assays could potentially replace protein immunoassays in many applications. Previous studies have demonstrated the utility of liquid chromatography–multiple-reaction monitoring–mass spectrometry (LC-MRM/MS) for the quantification of proteins in biological samples, and many examples of the accuracy of these approaches to quantify supplemented analytes have been reported. However, a direct comparison of multiplexed assays that use LC-MRM/MS with established immunoassays to measure endogenous proteins has not been reported. METHODS We purified HDL from the plasma of 30 human donors and used label-free shotgun proteomics approaches to analyze each sample. We then developed 2 different isotope-dilution LC-MRM/MS 6-plex assays (for apoliporoteins A-I, C-II, C-III, E, B, and J): 1 assay used stable isotope-labeled peptides and the other used stable isotope-labeled apolipoprotein A-I (an abundant HDL protein) as an internal standard to control for matrix effects and mass spectrometer performance. The shotgun and LC-MRM/MS assays were then compared with commercially available immunoassays for each of the 6 analytes. RESULTS Relative quantification by shotgun proteomics approaches correlated poorly with the 6 protein immunoassays. In contrast, the isotope dilution LC-MRM/MS approaches showed correlations with immunoassays of r = 0.61–0.96. The LC-MRM/MS approaches had acceptable reproducibility (<13% CV) and linearity (r ≥0.99). Strikingly, a single protein internal standard applied to all proteins performed as well as multiple protein-specific peptide internal standards. CONCLUSIONS Because peak area ratios measured in multiplexed LC-MRM/MS assays correlate well with immunochemical measurements and have acceptable operating characteristics, we propose that LC-MRM/MS could be used to replace immunoassays in a variety of settings.

Funder

University of Washington

NIH

Tobacco-Related Disease Research Program

American Heart Association

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3