Patient-Based Real-Time Quality Control: Review and Recommendations

Author:

Badrick Tony1,Bietenbeck Andreas2,Cervinski Mark A34,Katayev Alex5,van Rossum Huub H67,Loh Tze Ping8

Affiliation:

1. RCPA Quality Assurance Programs, St. Leonards, Sydney, Australia

2. Institut für Klinische Chemie und Pathobiochemie Klinikum, Münich, Germany

3. Dartmouth-Hitchcock Medical Center, Lebanon, NH

4. Geisel School of Medicine at Dartmouth, Hanover, NH

5. Laboratory Corporation of America Holdings, Elon, NC

6. The Netherlands Cancer Institute, Amsterdam, the Netherlands

7. Huvaros, Amsterdam, the Netherlands

8. National University Hospital, Singapore

Abstract

Abstract For many years the concept of patient-based quality control (QC) has been discussed and implemented in hematology laboratories; however, the techniques have not been widely implemented in clinical chemistry. This is mainly because of the complexity of this form of QC, as it needs to be optimized for each population and often for each analyte. However, the clear advantages of this form of QC, together with the ongoing realization of the shortcomings of “conventional” QC, have driven a need to provide guidance to laboratories to assist in deploying patient-based QC. This overview describes the components of a patient-based QC system (calculation algorithm, block size, truncation limits, control limits) and the relationship of these to the analyte being controlled. We also discuss the need for patient-based QC system optimization using patient data from the individual testing laboratory to reliably detect systematic errors while ensuring that there are few false alarms. The term patient-based real-time quality control covers many activities that use data from patient samples to detect analytical errors. These activities include the monitoring of patient population parameters such as the mean or median analyte value or using single within-patient changes such as the delta check. In this report, we will restrict the discussion to population-based parameters. This overview is intended to serve as a guide for the implementation of a patient-based QC system. The report does not cover the clinical evaluation of the population.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

Cited by 62 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3