Total-Variation Regularization Based Inverse Planning for Intensity Modulated Arc Therapy

Author:

Zhu Lei1,Niu Tianye1,Choi Kihwan2,Xing Lei3

Affiliation:

1. George W. Woodruff School, Nuclear and Radiological Engineering and Medical Physics Programs, Georgia Institute of Technology, Atlanta, Georgia 30332

2. Department of Electrical Engineering, Stanford University, Stanford, CA 94305

3. Department of Radiation Oncology, School of Medicine, Stanford University, Stanford, CA 94305

Abstract

Intensity modulated arc therapy (IMAT) delivers conformal dose distributions through continuous gantry rotation with constant or variable speed while modulating the field aperture shape and weight. The enlarged angular space and machine delivery constraints make inverse planning of IMAT more intractable as compared to its counterpart of fixed gantry IMRT. Currently, IMAT inverse planning is being done using two extreme methods: the first one computes in beamlet domain with a subsequent arc leaf sequencing, and the second proceeds in machine parameter domain with entire emphasis placed on a pre-determined delivery method without exploring potentially better alternative delivery schemes. Towards truly optimizing the IMAT treatment on a patient specific basis, in this work we propose a total-variation based inverse planning framework for IMAT, which takes advantage of the useful features of the above two existing approaches while avoiding their shortcomings. A quadratic optimization algorithm has been implemented to demonstrate the performance and advantage of the proposed approach. Applications of the technique to a prostate case and a head and neck case indicate that the algorithm is capable of generating IMAT plans with patient specific numbers of arcs efficiently. Superior dose distributions and delivery time are achieved with a maximum number of apertures of three for each field. As compared to conventional beamlet-based algorithms, our method regularizes the field modulation complexity during optimization, and permits us to obtain the best possible plan with a pre-set modulation complexity of fluences. As illustrated in both prostate and head-and-neck case studies, the proposed method produces more favorable dose distributions than the segment-based algorithms, by optimally accommodating the clinical need of intensity modulation levels for each individual field. On a more fundamental level, our formulation preserves the convexity of optimization and makes the search of the global optimal solution possible with a deterministic method.

Publisher

SAGE Publications

Subject

Cancer Research,Oncology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3