A Novel Trajectory of C7 Laminar Screws Determined Using Three-Dimensional Computed Tomography and Surgical Simulation Software: Comparison with a Pre-existing Trajectory

Author:

Lee Chee Kean,Li Quan You,Park JiwonORCID,Park Sang-MinORCID,Kim Ho-JoongORCID,Chang Bong-SoonORCID,Woo Byungjun,Yeom Jin S.ORCID

Abstract

Study Design: Examination using three-dimensional screw trajectory software and computed tomographic scans.Purpose: To evaluate the feasibility of a novel trajectory for C7 laminar screws and to compare it with an old trajectory.Overview of Literature: The previously reported trajectory of C7 laminar screws has a horizontal direction without a fixed target point. Our new trajectory has a cephalad direction with a fixed target point.Methods: Computed tomographic scans of a total of 50 male and 50 female patients were utilized. The placement of C7 laminar screws was activated employing the new and old trajectories. The success rate, the causes of failure, and the maximum allowable length of each trajectory were compared.Results: Employing the new trajectory, the success rates of the unilaminar and bilaminar screws were 93% and 83%, respectively, which were significantly better than the old trajectory (80%, <i>p</i><0.0001 and 70%, <i>p</i>=0.0003). The most prevalent cause of failure was laminar cortical breach followed by facet joint violation. The new trajectory also offered significantly longer maximum allowable screw length in unilaminar (32.5±4.3 mm vs. 26.5±2.6 mm, <i>p</i><0.001), bilaminar cephalic (29.5±3.8 mm vs. 25.9±2.6 mm, <i>p</i><0.0001) and bilaminar caudal (33.1±2.6 mm vs. 25.8±3.1 mm, <i>p</i><0.001) screws than the old trajectory. With the new and old trajectories, 70% vs. 6% of unilaminar, 60% vs. 2% of bilaminar caudal, and 32% vs. 4% of bilaminar cephalic screws could be protracted perfectly into the corresponding lateral mass without any laminar cortical or facet joint violation (<i>p</i><0.0001).Conclusions: The novel trajectory possesses a substantially higher success rate, longer maximum allowable screw length, and higher chance to be extended into the lateral mass (a condition known as a lamino-lateral mass screw) than the old trajectory.

Funder

Seoul National University Bundang Hospital

Publisher

Asian Spine Journal (ASJ)

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3