Effect of Vascular Activity in the Determination of Rate Constants for the Uptake of 18F-Labeled 2-Fluoro-2-Deoxy-D-Glucose: Error Analysis and Normal Values in Older Subjects

Author:

Evans A. C.1,Diksic M.1,Yamamoto Y. L.1,Kato A.1,Dagher A.1,Redies C.1,Hakim A.1

Affiliation:

1. Brain Imaging Centre, Montreal Neurological Institute and Hospital, and Department of Neurology and Neurosurgery, McGill University, Montreal, Canada

Abstract

Regional cerebral blood volume (CBV) can be calculated using data obtained during the kinetic analysis of 18F-labeled 2-fluoro-2-deoxy-d-glucose (FDG) uptake measured by positron emission tomography (PET). As a result the influence of vascular activity upon the determination of FDG rate constants can be minimized. The method is investigated by simulation experiments and by analysis of PET studies on seven older, healthy human volunteers aged 52–70 years. The accuracy of measured FDG rate constants k1, k2, and k3, obtained either by omitting the early portion of the uptake curve or by explicit inclusion of CBV as a fit parameter, is compared. The root mean square error in measured rate constant for the latter method is equivalent to that obtained by omitting the first 2.5–3 min of tissue data and neglecting the CBV term. Hence, added information about the physiological state of the tissue is obtained without compromising the accuracy of the (FDG) rate constant measurement. In hyperemic tissue the explicit determination of the vascular fraction results in more accurate estimates of the FDG rate constants. The ratio of CBV determined by this method to CBV obtained using C15O in six subjects with CBV in the normal range was 0.92 ± 0.32. A comparison of the CBV image obtained by this method with that obtained using C15O in an arteriovenous malformation case demonstrates the accuracy of the approach over a wide range of CBV values. The mean value for CBV fraction in gray matter obtained by this method in the older control group was 0.040 ± 0.014. Average gray matter rate constants obtained were k1 = 0.084 ± 0.012, k2 = 0.150 ± 0.071, and k3 = 0.099 ± 0.045 min−1.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Clinical Neurology,Neurology

Cited by 58 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3