Effects of whole-body vibration training in static and dynamic semi-squat patterns on the lower limb muscle activity

Author:

Liu Yuxiu,Fan Yongzhao,Chen Xiaohong

Abstract

AbstractThe decline in physical function and the deterioration of the neuromusculoskeletal system in older people can easily lead to reduced muscle strength and slower mobility in the joints of the lower limbs, increasing the incidence of chronic diseases such as muscle wasting disorders, osteoporosis, debilitation and fall and fracture. It may also affect the quality of life and functional independence of older people, and in serious cases, even directly threaten their health. This study was conducted to determine the differences in lower limb muscle activation characteristics between static semi-squat (SSS) and dynamic semi-squat (DSS) training in middle-aged and old women at different frequencies and amplitudes and to explore a personalized whole-body vibration (WBV) training instruction program suitable for them. Fifteen healthy middle-aged and old women (60.8 ± 4.18 years old) were recruited for SSS and DSS WBV training. Their muscle activity of the rectus femoris (RF), vastus medialis (VM), vastus lateralis (VL), biceps femoris (BF) and gastrocnemius (GS) were calculated using the BTS FreeEMG300 wireless surface electromyography (EMG), which participants were completed that the two different contraction patterns of squats on WBV training. The knee flexion was maintained at 45° while the subjects were performing the SSS training, while during the DSS training, the knee flexion fluctuates between 10° and 45°. The SSS exercise requires the subject to remain stationary in the squatting position and the DSS to be performed at a rhythm of 4 s/repetition, with 2 s of squatting, 1 s of standing up, and 1 s intervals. The vibration frequencies and amplitudes were changed to the WBV training intensity, and the vibration frequencies were set to 0 Hz, 30 Hz and 40 Hz, and the amplitudes were set to 0 mm, 2 mm and 4 mm. Each subject is randomised to participate in WBV training with 5 combinations of frequency and amplitude in both static and dynamic semi-squat patterns. These were 0 Hz 0 mm, 30 Hz 2 mm, 30 Hz 4 mm, 40 Hz 2 mm, 40 Hz 4 mm for the static and dynamic demi-squat patterns of WBV training. A two-way repeated measures ANOVA was applied to compare the changes in surface EMG of the lower limb muscles in different modes of SSS and DSS with WBV training. (1) Our results showed significantly interaction effects in the frequency × amplitude of root mean square (EMGrms) in GS (P < 0.05), while no significant differences were observed in the interaction effects of SSS/DSS patterns, frequencies and amplitude of RF, VM, VL and BF (P > 0.05). (2) Comparisons between groups showed that the EMGrms of the RF were significantly higher for the DSS than the SSS (P < 0.05). Additionally, the EMGrms of VL and BF at 30 Hz and 40 Hz were greater than 0 Hz (P < 0.05). Also, The EMGrms at 4 mm for the VM, VL and BF were significantly higher than 0 mm, the EMGrms at 4 mm for the VM and VL were significantly higher than 2 mm (P < 0.05), and the EMGrms at 2 mm of VL and BF were significantly higher than 0 mm (P < 0.05). (3) The results showed that WBV stimulation significantly increased the EMGrms of the GS in the SSS compared with the vibration free semi-squat alone (P < 0.05). However, there were no significant differences between WBV training protocols for SSS patterns with different frequencies and amplitudes (frequencies and amplitudes not were 0 Hz and 0 mm) (P > 0.05). Comparison of EMGrms for WBV training of the GS in DSS patterns showed that 40 Hz/4 mm was significantly higher than 0 Hz/0 mm (P < 0.05), but there was no significant difference between the remaining vibration conditions (P > 0.05). WBV training for DSS can significantly improve the activation of the RF compared to SSS pattern. Compared with no vibration, WBV could significantly improv the activity of the lower limb muscles. Additionally, an increase in amplitude from 2 to 4 mm could significantly improve VM and VL activation, while no significant improvement on lower limb muscle activation was observed for increasing vibration frequency from 30 to 40 Hz.

Publisher

Springer Science and Business Media LLC

Subject

Multidisciplinary

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3