Ultrasound dynamic monitoring of IVCD to guide application of CRRT in patients with renal failure combined with acute heart failure

Author:

Yu Guang,Tao Shaoyu,Jin Yingzhi,Li Wanxia,Hu Zanqun,Fang Xiaowei

Abstract

AbstractWe explored the application value of bedside ultrasound dynamic monitoring of the inferior vena cava diameter (IVCD) and collapse with sniff (inferior vena cava collapsibility index [IVCCI]) to guide dehydration adjustment in continuous renal replacement therapy (CRRT) in patients with combined renal failure and acute heart failure. We selected 90 patients with combined renal and acute heart failure who required CRRT in the intensive care unit (ICU) from January 2019 to June 2021. According to different blood volume assessment methods, patients were randomly divided into ultrasound, experience, and control groups. We compared serum creatinine, potassium, and N-terminal pro-brain natriuretic peptide (NT-proBNP) levels; time to improved heart failure symptoms; CRRT time; ventilator use; ICU length of stay; vasopressor use; and incidence of adverse events among groups. There were no significant differences in serum creatinine, potassium, and NT-proBNP levels in pairwise comparisons among groups before and after CRRT (P > 0.05). The time to improved heart failure symptoms, CRRT time, and ICU length of stay in the ultrasound and experience groups were lower than those in the control group; the differences were statistically significant (P < 0.05). Ventilator use duration was lower in the ultrasound and experience groups compared with the control group, with a statistically significant difference between the ultrasound and control groups (P < 0.05). The duration of vasopressor use in the ultrasound and control groups was lower than that in the experience group; the difference was statistically significant (P < 0.05). The incidence of adverse events was lower in the ultrasound group compared with the experience and control groups; the difference was statistically significant (P < 0.05). Ultrasound dynamic monitoring of IVCD and collapse with sniff can accurately assess blood volume status, and provide guidance for dehydration adjustments in CRRT and rapid relief of heart failure symptoms in patients with combined renal and acute heart failure.

Funder

The Health Commission Science and Technology Project of Jiangxi Province

Publisher

Springer Science and Business Media LLC

Subject

Multidisciplinary

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3