Author:
Small K. L.,Henthorn N. T.,Angal-Kalinin D.,Chadwick A. L.,Santina E.,Aitkenhead A.,Kirkby K. J.,Smith R. J.,Surman M.,Jones J.,Farabolini W.,Corsini R.,Gamba D.,Gilardi A.,Merchant M. J.,Jones R. M.
Abstract
AbstractThis paper presents the first plasmid DNA irradiations carried out with Very High Energy Electrons (VHEE) over 100–200 MeV at the CLEAR user facility at CERN to determine the Relative Biological Effectiveness (RBE) of VHEE. DNA damage yields were measured in dry and aqueous environments to determine that ~ 99% of total DNA breaks were caused by indirect effects, consistent with other published measurements for protons and photons. Double-Strand Break (DSB) yield was used as the biological endpoint for RBE calculation, with values found to be consistent with established radiotherapy modalities. Similarities in physical damage between VHEE and conventional modalities gives confidence that biological effects of VHEE will also be similar—key for clinical implementation. Damage yields were used as a baseline for track structure simulations of VHEE plasmid irradiation using GEANT4-DNA. Current models for DSB yield have shown reasonable agreement with experimental values. The growing interest in FLASH radiotherapy motivated a study into DSB yield variation with dose rate following VHEE irradiation. No significant variations were observed between conventional and FLASH dose rate irradiations, indicating that no FLASH effect is seen under these conditions.
Publisher
Springer Science and Business Media LLC
Reference59 articles.
1. National Cancer Registration & Analysis Service and Cancer Research UK. Chemotherapy, Radiotherapy and Tumour Resections in England: 2013–2014 Workbook. http://www.ncin.org.uk/cancer_type_and_topic_specific_work/topic_specific_work/main_cancer_treatments (2017)
2. NHS. (2020). Proton beam therapy. Available: https://www.england.nhs.uk/commissioning/spec-services/highly-spec-services/pbt/. Last accessed 28th Jul 2020.
3. Jones, R. M. Wakefield suppression in high gradient linacs for lepton linear colliders. Phys. Rev. ST Accel. Beams 12, 104801 (2009).
4. Jones, R. M. et al. Influence of fabrication errors on wake function suppression in NC X-band accelerating structures for linear colliders. New J. Phys. 11, 033013 (2009).
5. DesRosiers, C., Moskvin, V., Bielajew, A. F. & Papiez, L. 150–250 MeV electron beams in radiation therapy. Phys. Med. Biol. 45, 1781–1805 (2000).
Cited by
30 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献