AbstractThis study compared the characteristics and mortality of new implantation of cardiac implantable electronic device (CIED) between tertiary and non-tertiary hospitals. From national health insurance claims data in Korea, 17,655 patients, who underwent first and new implantation of CIED between 2013 and 2017, were enrolled. Patients were categorized into the tertiary hospital group (n = 11,560) and non-tertiary hospital group (n = 6095). Clinical outcomes including in-hospital death and all-cause death were compared between the two groups using propensity-score matched analysis. Patients in non-tertiary hospitals were older and had more comorbidities than those in tertiary hospitals. The study population had a mean follow-up of 2.1 ± 1.2 years. In the propensity-score matched permanent pacemaker group (n = 5076 pairs), the incidence of in-hospital death (odds ratio [OR]: 0.76, 95% confidence interval [CI]: 0.43–1.32, p = 0.33) and all-cause death (hazard ratio [HR]: 0.92, 95% CI 0.81–1.05, p = 0.24) were not significantly different between tertiary and non-tertiary hospitals. These findings were consistently observed in the propensity-score matched implantable cardioverter-defibrillator group (n = 992 pairs, OR for in-hospital death: 1.76, 95% CI 0.51–6.02, p = 0.37; HR for all-cause death: 0.95, 95% CI 0.72–1.24, p = 0.70). In patients undergoing first and new implantation of CIED in Korea, mortality was not different between tertiary and non-tertiary hospitals.
Publisher
Springer Science and Business Media LLC
Reference24 articles.
1. Uslan, D. Z. et al. Temporal trends in permanent pacemaker implantation: a population-based study. Am. Heart J. 155, 896–903 (2008).
2. Kurtz, S. M. et al. Implantation trends and patient profiles for pacemakers and implantable cardioverter defibrillators in the United States: 1993–2006. Pacing Clin. Electrophysiol. 33, 705–711 (2010).
3. Mond, H. G. & Proclemer, A. The 11th world survey of cardiac pacing and implantable cardioverter-defibrillators: calendar year 2009—a World Society of Arrhythmia’s project. Pacing Clin. Electrophysiol. 34, 1013–1027 (2011).
4. Asia Pacific Heart Rhythm Society. APHRS White Book 2016 http://www.aphrs.org/attachments/article/42/APHRS%20White%20Book%202016.pdf (2016).
5. Chun, C., Kim, S. J. L. & Lee, S. Republic of Korea: health system review. Health Syst. Transit. 11, 1–184 (2009).
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献