Author:
Rahman K. M. Taufiqur,Butzin Nicholas C.
Abstract
AbstractQuantifying bacterial cell numbers is crucial for experimental assessment and reproducibility, but the current technologies have limitations. The commonly used colony forming units (CFU) method causes a time delay in determining the actual numbers. Manual microscope counts are often error-prone for submicron bacteria. Automated systems are costly, require specialized knowledge, and are erroneous when counting smaller bacteria. In this study, we took a different approach by constructing three sequential generations (G1, G2, and G3) of counter-on-chip that accurately and timely count small particles and/or bacterial cells. We employed 2-photon polymerization (2PP) fabrication technology; and optimized the printing and molding process to produce high-quality, reproducible, accurate, and efficient counters. Our straightforward and refined methodology has shown itself to be highly effective in fabricating structures, allowing for the rapid construction of polydimethylsiloxane (PDMS)-based microfluidic devices. The G1 comprises three counting chambers with a depth of 20 µm, which showed accurate counting of 1 µm and 5 µm microbeads. G2 and G3 have eight counting chambers with depths of 20 µm and 5 µm, respectively, and can quickly and precisely count Escherichia coli cells. These systems are reusable, accurate, and easy to use (compared to CFU/ml). The G3 device can give (1) accurate bacterial counts, (2) serve as a growth chamber for bacteria, and (3) allow for live/dead bacterial cell estimates using staining kits or growth assay activities (live imaging, cell tracking, and counting). We made these devices out of necessity; we know no device on the market that encompasses all these features.
Funder
National Science Foundation
Publisher
Springer Science and Business Media LLC
Reference90 articles.
1. Thunyaporn, R., Doh, I. & Lee, D. W. Multi-volume hemacytometer. Sci. Rep. 11(1), 1–9 (2021).
2. Ongena, K. et al. Determining cell number during cell culture using the Scepter cell counter. JoVE 45, e2204 (2010).
3. Phelan, M. C. & Lawler, G. Cell counting. Curr. Protocols Cytometry 1, A.3A.1-A.3A.4 (1997).
4. Brugger, S. D. et al. Automated counting of bacterial colony forming units on agar plates. PLoS ONE 7(3), e33695 (2012).
5. Blodgett, R. J. Mathematical treatment of plates with colony counts outside the acceptable range. Food Microbiol. 25(1), 92–98 (2008).
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献