Author:
Vivek K. S.,Dar Mohammad Adil,Ali M. I.,Manohar M.,Sreedhar Babu T.
Abstract
AbstractA comprehensive test program was performed to experimentally investigate the effect of CFRP strengthening on the axial strength and stability of CFS plain angle short columns subjected to monotonic axial compression. A total of 28 specimens were tested by varying the CFRP strengthening configurations for different column heights. Both uni-directional (CF_UD) and bi-directional (CF_BD) CFRP were considered. The influence of various parameters such as the type of CFRP, fiber orientation, and number of CFRP layers was investigated and discussed in detail. For single layer (ply) of CFRP, CF_UD-0° strengthening configuration resulted in maximum increase of axial capacity by 58.33% and 45.72% (in comparison to bare steel specimens), corresponding to 0.5 m and 1.0 m column lengths respectively. All the bare steel and skin-strengthened specimens failed predominantly due to torsional–flexural buckling mode. Additional layer of CFRP wrapping was found to enhance the axial capacity further and CF_UD-0°/BD was found to possess greater capacity in the case of double layer of CFRP. Adopting cardboard in-fill in addition to CF_UD-0° wrap has prevented the torsional mode of buckling and resulted in a peak increase of axial capacity by 192.55% and 240.61% corresponding to 500 mm and 100 mm long specimens, respectively.
Funder
All India Council for Technical Education
University of Sheffield Institutional Open Access Fund
Publisher
Springer Science and Business Media LLC