Abstract

AbstractComparative studies between artificial eyeball phantoms and in-vivo human subjects were carried out to better understanding the structural deformation of the cornea under varying intraocular pressure (IOP). The IOP-induced deformation and the tension of the cornea were measured by using an optical coherence tomography and noncontact tonometer readings, respectively. The dependence of the central cornea thickness (CCT) and corneal radius of curvature (CRC) on the IOP differed significantly between the full eyeball phantom (FEP) and cornea eyeball phantom (CEP) models. While the CCT changes were very similar between the two models, the relation between the CRC and the IOP was dependent on the type of eye phantom. For the CEP, the CRC drastically decreased as internal pressure increased. However, we found that the changes in the CRC of FEP was dependent on initial CCT under zero IOP (CCT0). When CCT0 was less than 460 μm, the CRC slightly decreased as IOP increased. Meanwhile, the CRC increased as IOP increased if CCT0 was 570 μm. A constitutive mechanical model was proposed to describe the response of the cornea accompanied by the changes in IOP. In vivo measurements on human subjects under both noninvasive and invasive conditions revealed that the relation between the CRC on the IOP is much closer to those observed from FEP. Considering the observed structural deformation of human cornea, we found that FEP mimics the human eye more accurately than the CEP. In addition, the tonometry readings of IOP show that the values from the CEP were overestimated, while those from the FEP were not. For these reasons, we expect that the FEP could be suitable for the estimation of true IOP and allow performance testing of tonometers for medical checkups and other clinical uses.

Funder

Korea Research Institute of Standards and Science

Ministry of Science and ICT (MSIT)

Ministry of Food and Drug Safety (MFDS)

Publisher

Springer Science and Business Media LLC

Subject

Multidisciplinary

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Predicting intraocular pressure utilizing highly nonlinear solitary waves as inputs to a CNN;Health Monitoring of Structural and Biological Systems XVIII;2024-05-09

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3