Reproducibility of APT-weighted CEST-MRI at 3T in healthy brain and tumor across sessions and scanners

Author:

Wu Yulun,Wood Tobias C.,Derks Sophie H. A. E.,Pruis Ilanah J.,van der Voort Sebastian,van Zanten Sophie E. M. Veldhuijzen,Smits Marion,Warnert Esther A. H.

Abstract

AbstractAmide proton transfer (APT)-weighted chemical exchange saturation transfer (CEST) imaging is a recent MRI technique making its way into clinical application. In this work, we investigated whether APT-weighted CEST imaging can provide reproducible measurements across scan sessions and scanners. Within-session, between-session and between scanner reproducibility was calculated for 19 healthy volunteers and 7 patients with a brain tumor on two 3T MRI scanners. The APT-weighted CEST effect was evaluated by calculating the Lorentzian Difference (LD), magnetization transfer ratio asymmetry (MTRasym), and relaxation-compensated inverse magnetization transfer ratio (MTRREX) averaged in whole brain white matter (WM), enhancing tumor and necrosis. Within subject coefficient of variation (COV) calculations, Bland–Altman plots and mixed effect modeling were performed to assess the repeatability and reproducibility of averaged values. The group median COVs of LD APT were 0.56% (N = 19), 0.84% (N = 6), 0.80% (N = 9) in WM within-session, between-session and between-scanner respectively. The between-session COV of LD APT in enhancing tumor (N = 6) and necrotic core (N = 3) were 4.57% and 5.67%, respectively. There were no significant differences in within session, between session and between scanner comparisons of the APT effect. The COVs of LD and MTRREX were consistently lower than MTRasym in all experiments, both in healthy tissues and tumor. The repeatability and reproducibility of APT-weighted CEST was clinically acceptable across scan sessions and scanners. Although MTRasym is simple to acquire and compute and sufficient to provide robust measurement, it is beneficial to include LD and MTRREX to obtain higher reproducibility for detecting minor signal difference in different tissue types.

Funder

Brain Tumour Charity

Stichting Semmy

Nederlandse Organisatie voor Wetenschappelijk Onderzoek

Publisher

Springer Science and Business Media LLC

Subject

Multidisciplinary

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3