Author:
Nienhaus Florian,Piotrowski Tobias,Nießing Bastian,König Niels,Schmitt Robert H.
Abstract
AbstractPhase contrast is one of the most important microscopic methods for making visible transparent, unstained cells. Cell cultures are often cultivated in microtiter plates, consisting of several cylindrical wells. The surface tension of the culture medium forms a liquid lens within the well, causing phase contrast conditions to fail in the more curved edge areas, preventing cell observation. Adaptive phase contrast microscopy is a method to strongly increase the observable area by optically compensating for the meniscus effect. The microscope’s condenser annulus is replaced by a transmissive LCD to allow dynamic changes. A deformable, liquid-filled prism is placed in the illumination path. The prism’s surface angle is adaptively inclined to refract transmitted light so that the tangential angle of the liquid lens can be compensated. Besides the observation of the phase contrast image, a beam splitter allows to simultaneously view condenser annulus and phase ring displacement. Algorithms analyze the displacement to dynamically adjust the LCD and prism to guarantee phase contrast conditions. Experiments show a significant increase in observable area, especially for small well sizes. For 96-well-plates, more than twelve times the area can be examined under phase contrast conditions instead of standard phase contrast microscopy.
Funder
Bundesministerium für Wirtschaft und Energie
Fraunhofer-Institut für Produktionstechnologie IPT
Publisher
Springer Science and Business Media LLC
Reference25 articles.
1. Zernike, F. Phase contrast, a new method for the microscopic observation of transparent objects. Physica 9, 686–698. https://doi.org/10.1016/S0031-8914(42)80035-X (1942).
2. Bennet, A. H., Jupnik, H., Osterberg, H., Richards, O. W. & Baez, A. V. Phase microscopy principles and applications. Am. J. Phys. 20, 318–319. https://doi.org/10.1119/1.1933224 (1952).
3. Horn, E. R. Z. Phase-contrast light microscopy of living cells cultured in small volume (2006).
4. ANSI American National Standards Institute, SLAS Society for Laboratory Automation and Screening. Microplates—Well Positions (2004).
5. Wright, P. F., Gall, D. & Kelly, W. A. Effect of meniscus formation and duplicate sample placement configurations on the variability of measurement by three microtiter plate photometers. J. Immunol. Methods 81, 83–93. https://doi.org/10.1016/0022-1759(85)90124-3 (1985).
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献