Author:
Fu Zhiyang,Tseng Hsin Wu,Vedantham Srinivasan
Abstract
AbstractThe feasibility of full-scan, offset-detector geometry cone-beam CT has been demonstrated for several clinical applications. For full-scan acquisition with offset-detector geometry, data redundancy from complementary views can be exploited during image reconstruction. Envisioning an upright breast CT system, we propose to acquire short-scan data in conjunction with offset-detector geometry. To tackle the resulting incomplete data, we have developed a self-supervised attenuation field network (AFN). AFN leverages the inherent redundancy of cone-beam CT data through coordinate-based representation and known imaging physics. A trained AFN can query attenuation coefficients using their respective coordinates or synthesize projection data including the missing projections. The AFN was evaluated using clinical cone-beam breast CT datasets (n = 50). While conventional analytical and iterative reconstruction methods failed to reconstruct the incomplete data, AFN reconstruction was not statistically different from the reference reconstruction obtained using full-scan, full-detector data in terms of image noise, image contrast, and the full width at half maximum of calcifications. This study indicates the feasibility of a simultaneous short-scan and offset-detector geometry for dedicated breast CT imaging. The proposed AFN technique can potentially be expanded to other cone-beam CT applications.
Funder
National Cancer Institute
Publisher
Springer Science and Business Media LLC
Reference34 articles.
1. Lindfors, K. K. et al. Dedicated breast CT: Initial clinical experience. Radiology 246, 725–733 (2008).
2. O’Connell, A. M., Karellas, A. & Vedantham, S. The potential role of dedicated 3D breast CT as a diagnostic tool: Review and early clinical examples. Breast J. 20, 592–605 (2014).
3. Karellas, A., Lo, J. Y. & Orton, C. G. Cone beam x-ray CT will be superior to digital x-ray tomosynthesis in imaging the breast and delineating cancer. Med. Phys. 35, 409–411 (2008).
4. Vedantham, S., Tseng, H.-W., Konate, S., Shi, L. & Karellas, A. Dedicated cone-beam breast CT using laterally-shifted detector geometry: Quantitative analysis of feasibility for clinical translation. J. X-Ray Sci. Technol. 28, 405–426 (2020).
5. Yang, K., Huang, S.-Y., Packard, N. J. & Boone, J. M. Noise variance analysis using a flat panel x-ray detector: A method for additive noise assessment with application to breast CT applications. Med. Phys. 37, 3527–3537 (2010).