Simultaneous experimental evaluation of pulse shape and deadtime phenomenon of GM detector

Author:

Almutairi Bader,Alam Syed,Goodwin Cameron S.,Usman Shoaib,Akyurek Tayfun

Abstract

AbstractAnalysis of several pulse shape properties generated by a Geiger Mueller (GM) detector and its dependence on applied voltage was performed. The two-source method was utilized to measure deadtime while simultaneously capturing pulse shape parameters on an oscilloscope. A wide range of operating voltages (600–1200 V) beyond the recommended operating voltage of 900 V was investigated using three radioactive sources (204Tl, 137Cs, 22Na). This study investigates the relationship between operating voltage, pulse shape properties, and deadtime of the detector. Based on the data, it is found that deadtime decreases with increasing voltage from 600 to 650 V. At these low voltages (600–650 V), the collection time was long, allowing sufficient time for some recombination to take place. Increasing the voltage in this range decreased the collection time, and hence deadtime decreased. It is also observed that rise and fall time were at their highest at these applied voltages. Increasing the voltage further would result in gas multiplication, where deadtime and pulse width are observed to be increasing. After reaching the maximum point of deadtime (~ 250 µs at ~ 700 V), deadtime started to exponentially decrease until a plateau was reached. In this region, it is observed that detector deadtime and operating voltage show a strong correlation with positive pulse width, rise and fall time, cycle mean, and area. Therefore, this study confirms a correlation between detector deadtime, operating voltage, and pulse shape properties. The results will validate our hypothesis that deadtime phenomena at different operating voltages are phenomenologically different.

Publisher

Springer Science and Business Media LLC

Subject

Multidisciplinary

Reference29 articles.

1. Geiger, H. On the scattering of the α-particles by matter. Proc. R. Soc. Lond. A 81, 174–177 (1908).

2. Geiger, H. & Müller, W. Electron counting tube for the measurement of the weakest radioactivities. The Sciences 16, 617–618 (1928).

3. Skinner, S. M. The efficiency of the tube counter. Phys. Rev. 48, 438–447 (1935).

4. Knoll, G. F. Radiation Detection and Measurement (Wiley, New York, 2010).

5. Muller, J. W. Dead-time problems. Nucl. Instrum. Methods 112, 47–57 (1973).

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3