Abstract
AbstractAlthough digital examination of the cervix is the standard method used worldwide for evaluating the progress of delivery, it is subjective. Transperineal ultrasound (TPU) is combined with digital evaluation for accurate assessment of fetal descent and rotation of the advanced part of the fetus. This retrospective study aimed to clarify the impact of introducing TPU on perinatal outcomes at Mie University Hospital. We analyzed singleton pregnant women who underwent delivery management at our hospital between April 2020 and March 2021. Perinatal outcomes were compared between patients who used TPU (TPU+ group) and those who did not (TPU− group). The angle of progression and head direction were measured. The rate of vaginal delivery was significantly increased (90.9% vs. 71.6%; P = 0.0017), and the second stage of labor was significantly prolonged in the TPU+ group (148.1 vs. 75.8 min; P < 0.0001). A significant difference was observed in termination in the latent phase between the TPU+ group [3/8 (37.5%) cases] and TPU− group [20/25 (80.0%) cases] (P = 0.036). The rate of vaginal delivery can be increased through accurate evaluation of the progress of delivery with TPU.