Investigation of intraocular pressure of the anterior chamber and vitreous cavity of porcine eyes via a novel method

Author:

Nagae Koji,Sawamura Hiromasa,Aihara Makoto

Abstract

AbstractTo evaluate a new method of measuring the intraocular pressure (IOP) in the vitreous cavity. IOPs in the anterior chamber and vitreous cavities of 24 porcine eyes (12 eyes with lenses and 12 eyes without lenses) were measured directly, continuously, and simultaneously. We used a needle as a part of the pressure sensor to measure the anterior chamber IOP and a disk-shaped sensor to measure the vitreous cavity IOP. A significant group-by-condition interaction on the vitreous cavity IOP between the two groups (phakia and aphakia) and four conditions of anterior chamber IOP were observed (F[3,258] = 5.8564, p < 0.001). A positive correlation was observed between the vitreous cavity IOP and anterior chamber IOP in both the phakia group (R = 0.96, p < 0.001) and the aphakia group (R = 0.97, p < 0.001). No significant correlation was observed between the ΔIOPv-a (vitreous cavity IOP − anterior chamber IOP) and anterior chamber IOP in either group (phakia group: R =  − 0.18, p = 0.034; aphakia group: R =  − 0.029, p = 0.73). The vitreous cavity IOP measured with the new sensor was well-correlated with the anterior chamber IOP in the physiological range tested.

Publisher

Springer Science and Business Media LLC

Subject

Multidisciplinary

Reference10 articles.

1. Aihara, M., Lindsey, J. D. & Wienreb, R. N. Reduction of intraocular pressure in mouse eyes treated with latanoprost. Investig. Ophthalmol. Vis. Sci. 43, 146–150 (2002).

2. John, S. W., Hagaman, J. R., MacTaggart, T. E., Peng, L. & Smithes, O. Intraocular pressure in inbred mouse strains. Investig. Ophthalmol. Vis. Sci. 38, 249–253 (1997).

3. Abrams, L. S., Vitale, S. & Jamepel, H. D. Comparison of three tonometers for measuring intraocular pressure in rabbits. Investig. Ophthalmol. Vis. Sci. 37, 940–944 (1996).

4. Hallberg, P., Santala, K., Lindén, C., Lindahl, O. A. & Eklund, A. Comparison of Goldmann applanation and applanation resonance tonometry in a biomicroscope-based in vitro porcine eye model. J. Med. Eng. Technol. 30, 345–352 (2006).

5. Hernández-Verdejo, J. L., Teus, M. A. & Bolivar, G. Simultaneous measurement of intraocular pressure in the anterior chamber and the vitreous cavity. Acta Ophthalmol. 88, e265–e268 (2010).

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3