Author:
Sun Fei,Cheng Wei,Zhao Bao-hong,Song Gui-Qiu,Lin Zeng
Abstract
AbstractScrew loosening is one of the most common clinical problems of dental implants. Research on the influencing factors of screw loosening is very important to prevent screw loosening. The purpose of this in vitro study was to evaluate the influence of liquid contamination on the screw loosening. According to the contamination condition, forty-five abutment screws were divided into three groups (n = 15): no contamination, artificial saliva contamination, and mouthwash contamination. The preload and friction coefficient of the abutment screws were recorded. Then, the reverse torque values (RTVs) and settlement were measured after 3.0 × 105 and 6.0 × 105 cycles. The surface wear of the screws was analyzed. Finally, the stress distribution of the abutment screws was calculated by finite element analysis (FEA). The results showed that fluid contamination reduced the friction coefficient, increased the preload, decrease the settlement, improved resistance to screw loosening, and reduced wear on the thread surface. Appropriate antimicrobial lubrication may improve the anti-loosening performance of abutment screws and prevent excessive wear on the threaded surface.
Funder
National Natural Science Foundation of China
Chinese Academy of Sciences-WEGO Research Development Plan
Fundamental Research Funds for the Central Universities
Publisher
Springer Science and Business Media LLC
Reference42 articles.
1. Stüker, R. A., Teixeira, E. R., Beck, J. C. & Costa, N. P. Preload and torque removal evaluation of three different abutment screws for single standing implant restorations. J. Appl. Oral Sci. 16(1), 55–58 (2008).
2. Jemt, T. et al. Osseointegrated implants for single tooth replacement: A 1-year report from a multicenter prospective study. Int. J. Oral Maxillofac. Implants 6(1), 29–36 (1991).
3. Pjetursson, B., Asgeirsson, A., Zwahlen, M. & Sailer, I. Improvements in implant dentistry over the last decade: Comparison of survival and complication rates in older and newer publications. Int. J. Oral Maxillofac. Implants 29, 308–324 (2014).