Author:
Rokohl Alexander C.,Trester Marc,Naderi Parsa,Loreck Niklas,Zwingelberg Sarah,Bucher Franziska,Pine Keith R.,Heindl Ludwig M.
Abstract
Abstract
Purpose
To evaluate morphological alterations of meibomian glands (MGs) in the dry anophthalmic socket syndrome (DASS).
Methods
Fifteen unilateral anophthalmic patients wearing cryolite glass prosthetic eyes were enrolled. All patients with clinical blepharitis or other significant eyelid abnormalities were excluded. In vivo laser scanning confocal microscopy (LSCM) of the MGs in the lower eyelids both on the anophthalmic side and the healthy fellow eye was performed to quantify acinar unit density, acinar unit diameter, acinar unit area, meibum secretion reflectivity, the inhomogeneous appearance of the glandular interstice, and inhomogeneous appearance of the acinar walls.
Results
The lower eyelids of the anophthalmic sockets revealed a significant reduction of the acinar unit density (p = 0.003) as well as a significantly more inhomogeneous appearance of the periglandular interstices (p = 0.018) and the acinar unit walls (p = 0.015) than the healthy fellow eyelid. However, there were no significant differences regarding the acinar unit diameter, acinar unit area, and meibum secretion reflectivity of the MGs on the anophthalmic side compared to the healthy fellow eyelid (p ≥ 0.05, respectively).
Conclusions
The eyelids of anophthalmic sockets without clinical blepharitis demonstrate a reduced density of MG acinar units and a more inhomogeneous appearance of the periglandular interstices and the acinar unit walls. This can cause meibomian gland dysfunction contributing to DASS and suggests early treatment of these symptomatic patients, even in the clinical absence of any blepharitis signs.
Publisher
Springer Science and Business Media LLC
Reference43 articles.
1. Pine K, Sloan B, Stewart J, Jacobs RJ. A survey of prosthetic eye wearers to investigate mucoid discharge. Clin Ophthalmol. 2012;6:707–13.
2. Pine KR, Sloan B, Jacobs RJ. Deposit buildup on prosthetic eyes and implications for conjunctival inflammation and mucoid discharge. Clin Ophthalmol. 2012;6:1755–62.
3. Pine KR, Sloan B, Jacobs RJ. Biosocial profile of New Zealand prosthetic eye wearers. N. Z Med J. 2012;125:29–38.
4. Pine KR, Sloan B, Jacobs RJ. The development of measurement tools for prosthetic eye research. Clin Exp Optom. 2013;96:32–8.
5. Pine KR, Sloan B, Stewart J, Jacobs RJ. The response of the anophthalmic socket to prosthetic eye wear. Clin Exp Optom. 2013;96:388–93.
Cited by
13 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献